![Crane Merchandising Systems BevMAX 4 Series Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/crane-merchandising-systems/bevmax-4-series/bevmax-4-series_technical-manual_2679246023.webp)
22 of 97
scroll to the key number you desire to change.
Press key number 4 with the key number
showing you wish to change (i.e. Select A1 #)
and the # will start blinking. Press key number 2
or 3 to scroll between “Select A1 0” and “Select
A1 1”. Press key number 4 with the display
showing the setting you wish to use. Display will
return to “Select A1 1”. Press key number 1 to
return to “Selection”. Press key number 2 to
scroll to “Less Amount”.
“Less Amount”
- Discount Amount (Price)
This function is used to set the discount amount
(price) for selection(s) and times set. Press key
number 4 and “##.##” will be displayed, where
“##.##” is the current discount price that is set.
Press key number 2 or 3 to change the price (00.00
to 99.99). Press key number 4 with the display
showing the price setting you wish to use. Display
will show price. Press key number 1 to return to
“Less Amount”. Press key number 1 to return to
“Select Discount”. Press key number 2 to scroll to
“Health Setting”.
Health Safety” – HEALTH SETTING
ROUTINE
This function is used to enable the health protection
feature for product when needed. When enabled it
operates as follows:
1. Cabinet temperature must be maintained at 41º
F (5º C) or below for product to be vended while
in normal operation. If the cabinet temperature
exceeds 41º F, and fails to return to 41º F or
below for 15 minutes the controller will issue a
“Health Code” error and disable vending of health
protected products.
2. After door closure, (refill or service) the machine
has 30 minutes to pull down to 45º F (7º C). If the
machine has not reached 45º F (7º C) after 30
minutes the controller will issue a “Health Timer”
error. Once a health time error is activated the
controller will not allow product to be delivered.
After 30 minutes if the temperature is 45º F or
less, but not 41º F the controller will set a 15
minute timer. During this time, if the cabinet
temperature falls below 41º F (5º C) the controller
will allow health guarded product to be delivered.
If the temperature doesn’t fall below 41º F (5º C)
the controller will issue a “Health Code” error and
disable vending of health protected products.
3. Power loss for 30 minutes or longer will result in
automatic “Health Code” error activation and
disable vending of health protected products
upon power up.
4. Power loss less than 30 minutes. Once the
machine regains power, if the cabinet
temperature is 45º F (7º C) or less the controller
will allow product to be dispensed. The controller
will allow an additional 15 minutes for the
temperature to pull down to 41º F (5º C). If the
temperature doesn’t reach 41º F (5º C) or less
after the 15 minute period the controller will issue
a “Health Code” error and disable vending of
health protected products. If the temperature is
greater than 45º F (7º C) on power up the
controller will automatically set a “Health Code”
error and disable vending of health protected
products.
5. Power loss less than 15 minutes. On power
up the controller will allow vending. If the
cabinet temperature doesn’t reach 41º F (5º
C) or less in 15 minutes the controller will
issue a “Health Code” error and disable
vending of health protected products.
To enable, with “Health Setting” on display press key
number 4 will enter “Enable #”.
“Enable #”
– Health Enable Routine
This function is used to enable the Health
Protection feature. When enabled, protected
selections will only be allowed to vend if health
constraints listed above are met. Press key
number 4 and the current “Enable” setting will be
displayed. Press key number 2 or 3 to scroll
between “Enable 0” and “Enable 1”. Press key
number 4 with the display blinking the setting you
wish to use. Display will return to “Enable #”. Press
key number 2 to scroll to “SELECT”.
“Selection”
– Selection(s) To Be Affected By Health
Protection
This function is used to set selection(s) which will be
protected by the Health Protection constraints. Press
key number 4 and “All Selections” will be displayed.
Press key number 2 to scroll through “All Selections,
A, B, C, D, and E”. Press key number 4 with the
setting you wish to enter. Selecting “A, B, C, D, or E”
will allow you to choose settings for that tray.
Example: With “A” showing on display press key
number 4. Display will show “All Selections #”, press
key number 2 to scroll through “A All Selections #,
Select A1 #, Select A2 #, Select A3 #, etc… With the
setting you wish to change press key number 4 and
the # will start blinking. Press key number 2 to scroll
between “0” disabled and “1” enabled. With the
setting you wish to use showing on the display press
key number 4. Display will return to “A All Selections
# or Select A# #”. Press key number 1 to return to
“Selection”. Press key number 1 to return to “Health
Safety”. Press key number 2 to scroll to “Over-ride
Switch”
“Over-ride Switch” - MANUAL SWITCH
OVERRIDE ROUTINE
This function is used to allow a key switch to override
some of the settings stored for normal operations. This
function can be programmed to control one or several
of the following features: Free Vend Enable, Selection
Blocking, Discount Pricing, and Lighting Control. Press
key number 4 and the display will show “Free Vend #”.
Содержание BevMAX 4 Series
Страница 52: ...51 of 104 INCORRECT CHANGE DISPENSED ...
Страница 53: ...52 of 104 SELECTION WILL NOT VEND Use DN Factory Diagnostics to check plunger arm replace if necessary ...
Страница 71: ...70 of 104 ...
Страница 72: ...71 of 104 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 5C ...
Страница 74: ...73 of 104 CABINET DETAIL PRODUCT AREA 3 2B 12 11 6 7 9 2A 8 5 14 11 ...
Страница 76: ...75 of 104 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 14 12 2 10 15 8 ...
Страница 80: ...79 of 104 DELIVERY PICKER CUP ASSEMBLY 11 1 2 21 10 5 16 14 15 17 4 7 12 13 19 6 19 20 9 8 19 3 22 ...
Страница 82: ...81 of 104 SERVICE DOOR OUTSIDE 3 4 12 18 20 25 5 7 8B 8B 23 9 15 14 18 17 8A 21 16 13 26 19D 6 10 24 27 19B 1 ...
Страница 86: ...85 of 104 GATE TRAY DETAIL 8 7 11 1 2 4 6 12 13 14 10 9 3 ...
Страница 96: ...95 of 104 ELECTRONICS Coke BevMax 4 EXE Control Boards 3 1 7 5 4 6 7 Executive 4 pin interface added ...
Страница 98: ...97 of 104 HARNESSES 6 8 2 7 1 4 5 9 22 16 15 10 19 14 21 17 18 13 23 24 20 3 ...
Страница 100: ...99 of 104 ...