37 of 104
b. Plunger
Hits
Chassis.
i. Check tray is level and secured to tray supports.
ii. Check
harness
connections.
iii. Check X motor (bottom right).
iv. Check belt tension. Look for the belt to slip.
v. Check shelf adjust in DN Factory Diagnostics BevMax Setup Coke Factory Setup Set
Shelf Offset.
c. Plunger Stays Out.
i. Check for syrup or dirt build up.
ii. Check
Harness
connections.
iii. Replace cup assy.
3. Delivery Cup Assembly Will Not Go Home.
a. Is there a “Vend Mechanism” error on the display when the door has been opened?
i. If yes check the “Y” (lower) and “X” (top far left) home switches.
1. In Test Mode/ Test Vend with the top door switch (PI) pressed in:
a. At the home position the “Y” (lower) home switch will light a green LED on
the control board.
b. At the home position the “X” (top far left) home switch will light an amber
LED on the control board.
i. Adjust the X drive belt at the bottom left belt clamp.
4. Elevator will not move vertically.
a. Perform TEST MODE/TEST VEND to test movement.
b. Check left side door switch.
i. Is it functioning.
ii. Is it being made when door is closed.
c. Check the Delivery Cup Plunger & Plunger Home Switch.
i. If plunger arm is stuck out it will shut down XY delivery system.
ii. If plunger arm home switch fails it will shut down XY delivery system.
d. Check the 10 pin harness connector to the “Y” motor.
e. Check
rollers.
f. Check Y motor harness and motor.
g. Check E-Chain harness.
h. Replace control board.
5. Elevator will not move horizontally.
a. Perform TEST MODE/TEST VEND to test movement.
b. Check left side door switch
i. Is it functioning.
ii. Is it being made when door is closed.
c. Check the lower and top far left home switches.
i. In Test Vend/Position Test with the left door switch (PI) pressed in:
1. At the home position the “Y” (lower) home switch will light a green LED on the
control board.
2. At the home position the “X” (top far left) home switch will light an amber LED on
the control board.
a. Adjust the X drive belt.
d. Check the Delivery Cup Plunger & Plunger Home Switch
i. If plunger arm is stuck out it will shut down XY delivery system.
ii. If plunger arm home switch fails it will shut down XY delivery system.
e. Check
rollers.
f. Check X motor harness and motor.
g. Replace control board.
Содержание BevMAX 4 Series
Страница 52: ...51 of 104 INCORRECT CHANGE DISPENSED ...
Страница 53: ...52 of 104 SELECTION WILL NOT VEND Use DN Factory Diagnostics to check plunger arm replace if necessary ...
Страница 71: ...70 of 104 ...
Страница 72: ...71 of 104 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 5C ...
Страница 74: ...73 of 104 CABINET DETAIL PRODUCT AREA 3 2B 12 11 6 7 9 2A 8 5 14 11 ...
Страница 76: ...75 of 104 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 14 12 2 10 15 8 ...
Страница 80: ...79 of 104 DELIVERY PICKER CUP ASSEMBLY 11 1 2 21 10 5 16 14 15 17 4 7 12 13 19 6 19 20 9 8 19 3 22 ...
Страница 82: ...81 of 104 SERVICE DOOR OUTSIDE 3 4 12 18 20 25 5 7 8B 8B 23 9 15 14 18 17 8A 21 16 13 26 19D 6 10 24 27 19B 1 ...
Страница 86: ...85 of 104 GATE TRAY DETAIL 8 7 11 1 2 4 6 12 13 14 10 9 3 ...
Страница 96: ...95 of 104 ELECTRONICS Coke BevMax 4 EXE Control Boards 3 1 7 5 4 6 7 Executive 4 pin interface added ...
Страница 98: ...97 of 104 HARNESSES 6 8 2 7 1 4 5 9 22 16 15 10 19 14 21 17 18 13 23 24 20 3 ...
Страница 100: ...99 of 104 ...