background image

page 6

6. Wiring.

CAUTION

Be sure outlet box is properly grounded 

and that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with 
Local Codes or Ordinances and the National 
Electrical Code. If you are unfamiliar with electrical 
wiring or if the house/building wires are different 
colors than those referred to below, please use a 
qualified electrician.

Note: 

Excess lead wire length from the fan can be 

cut to the desired length and then stripped.

When downrod is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK

 wire from fan to 

BLACK

 wire from 

ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together 

from fan to 

BARE

/

GREEN

 wire from ceiling with 

wire connector provided.

Since this fan does not come with a light kit, you 
will need to cap off the 

BLUE 

wire with a wire 

connector (as shown with arrow in diagram). 
[

Note

: If you elect to purchase a light kit for the 

fan, the 

BLUE

 wire from the fan must be 

connected to the 

BLACK

 (or 

RED

) wire from the 

ceiling instead.]

*Wrap each wire connector separately with 
electrical tape as an extra safety measure.

This fan is remote control adaptable (remote control 
sold separately). 

wire

connector

black

black

white

white

blue

black supply wire

white supply wire

from

ceiling

from fan

ground 
(green or bare)

*

ground 
(green 
or bare)

7. Canopy Assembly.

Locate 2 screws on underside of hanging bracket 
and remove screw closest to the open end of the 
hanging bracket. Partially loosen the other screw. 
Lift canopy to hanging bracket. Place rounded part 
of slotted hole in canopy over loosened screw in 
hanging bracket and push up. Twist canopy to lock. 
Re-insert screw that was previously removed and 
then tighten both screws securely.

Slide canopy cover up to canopy, aligning rounded 
part of slotted holes in canopy cover with screw 
heads in bottom of canopy. Turn canopy cover to 
the right (clockwise) until it stops.

canopy

screw

hanging bracket

screw

canopy cover

Содержание YOR52

Страница 1: ...nging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 6 Blade Assembly pg 7 Switch Housing Assembly pgs 7 8 Testing Your Fan pg 8 Light Kit Assembly Optional pg 9 Trouble...

Страница 2: ...12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference...

Страница 3: ...against parts inventory that all parts have been included 2 Parts Inventory IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety a canopy 1 piece b hang...

Страница 4: ...ging bracket towards high point of ceiling Arrange electrical wiring around the back of the hanging bracket Note It is very important that you use the proper hardware when installing the hanging brack...

Страница 5: ...for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously removed Tighten yoke set screws and nuts securely Refer to diagram...

Страница 6: ...hanging bracket Turn the hanging ball slot until it lines up with the hanging bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or dea...

Страница 7: ...UE wire with a wire connector as shown with arrow in diagram Note If you elect to purchase a light kit for the fan the BLUE wire from the fan must be connected to the BLACK or RED wire from the ceilin...

Страница 8: ...ews Note Tighten blade arm screws twice a year blade arm screws lock washers motor housing blade arm blade blade attachment screws and washers 9 Switch Housing Assembly Remove 4 screws from outer edge...

Страница 9: ...ill set the fan to MEDIUM Third pull will set the fan to LOW Fourth pull will again set the fan to the OFF setting If fan does not function please refer to Troubleshooting section to solve any issues...

Страница 10: ...tch housing Connect BLACK wire from light kit fitter to BLUE or BLACK wire from switch housing Be sure molex connections snap together securely Refer to diagram b Connect male plug from the motor hous...

Страница 11: ...hipping of the product for repairs This warranty does not apply when damage from mechanical physical electrical or water abuse results in causing the malfunction Deterioration of finishes or other par...

Страница 12: ...dor P gs 4 5 Instalaci n el ctrica P g 6 Colocaci n de la cubierta decorativa P g 6 Colocaci n de las aspas P g 7 Instalaci n de la caja de encendido P gs 7 8 Verificaci n del funcionamiento del venti...

Страница 13: ...s superior al 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tama o corre...

Страница 14: ...incluyeron todas 2 Inventario de piezas RECORDATORIO IMPORTANTE Se tienen que utilizar las piezas provistas con este ventilador para una instalaci n adecuada y su seguridad a cubierta decorativa 1 un...

Страница 15: ...o Arreglar el alambrado el ctrico los cables en la parte de atr s del soporte y lejos de la abertura del soporte Nota Es muy importante usar los art culos de ferreter a correctos al instalar el soport...

Страница 16: ...introducir el perno y la clavija que se quitaron anteriormente Apretar los tornillos de fijaci n del cuello y la tuerca completamente Referirse al diagrama 2 Deslizar la cubierta del cuello y la cubi...

Страница 17: ...izar tornillo para madera para trabajos pesados arandela y arandela de seguridad no provistos para asegurar el bucle del cable de seguridad Si es necesario ajustar el bucle en el extremo del cable de...

Страница 18: ...s cables de la casa el edificio son de colores diferentes a los cuales se refieren a continuaci n favor de buscar un electricista calificado Nota Si la longitud del alambrado que sale del ventilador e...

Страница 19: ...petir el mismo procedimiento con los dem s brazos para las aspas Apretar bien todos los tornillos Nota Apretar los tornillos para los brazos para las aspas dos veces al a o placa de conexi n placa de...

Страница 20: ...en marcha ALTA El segundo tir n controla el ventilador para que se baje a marcha MEDIA El tercer tir n bajar el ventilador a marcha BAJA Con el cuarto tir n se APAGAR el ventilador de nuevo Si el vent...

Страница 21: ...la cubierta de la caja de encendido Conectar el cable NEGRO del conectador para el juego de luz al cable AZUL o NEGRO de la cubierta de la caja de encendido Asegurarse de que se conecten bien las con...

Страница 22: ...ventilador tenga da os por abuso mec nico f sico el ctrico o por agua resultando en su mal funcionamiento Se exenta espec ficamente el deterioro en el acabado u otras partes debido al tiempo o exposi...