SAFETY TIPS.

page 1

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel before you begin the fan 

installation or before servicing the fan or installing accessories.
 
1.        

 READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND SAVE THESE 

INSTRUCTIONS.

  

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and ANSI/NFPA 70-1999.  If you 

are unfamiliar with electrical wiring or if the house/building wires are different colors than those referred to in the instructions, please 
use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least seven (7) feet (2.13 meters) 

of clearance between the floor and the fan blade tips.  The fan should be mounted so that the tips of the blades are at least thirty (30) 
inches (76 centimeters) from walls or other upright structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 35 pounds (16 kilograms).  

The outlet box must be supported directly by the building structure.  Use only CETL (Canada) or ETL (USA) listed outlet boxes marked 
"FOR FAN SUPPORT."

  

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable for Fan Support of 15.9 kg 

(35 lb) or less," and use the mounting screws provided with the outlet box.  Most outlet boxes commonly used for the support of lighting 
fixtures are not acceptable for fan support and may need to be replaced.  Consult a qualified electrician if in doubt.
  

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are designed to accept only one 

12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 gauge or there is more than one house wire to 
connect to the corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.

WARNING

:  If using this fan in a WET location, this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit 

Interrupter (GFCI) to reduce the risk of personal injury, electrical shock or death.

5.         Electrical diagrams are for reference only.  Light kits that are not packed with the fan must be CETL (Canada) or ETL (USA) listed and 

marked suitable for use with the model fan you are installing.  Switches must be  CETL (Canada) or ETL (USA) general use switches.  
Refer to the instructions packaged with the light kits and switches for proper assembly.

      
6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box.  The wires 

should be spread apart with the grounded conductor and the equipment-grounding conductor on opposite sides of the outlet box.

  

WARNING

:  To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device or control fan speed with a 

full range dimmer switch.  [Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan.] 
  
8.        Do not operate the reverse switch until the fan has come to a complete stop.  
9.        Do not insert anything between the fan blades while they are rotating.
  

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.  Do not insert objects into the 

path of the blades.
  

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.

  
10.      Do not use detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most cleaning.
  

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts 

OTHER

 than those provided with this 

fan will void the warranty.
  
WARNING

:  

This fan MUST be installed with the safety cable provided with the fan. Failure to use the safety cable provided may result in 

personal injury, damage to the fan or damage to other property.
  

CAUTION

: Do NOT tamper with or attempt to repair LED component of fixture. The light source is designed for this specific application and 

should not be serviced by untrained personnel. If any servicing is required, call our customer service department.

11.      Light kit is dimmable to 10% with the remote/wall control included.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC 
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
 

* Reorient or relocate the receiving antenna.

 

* Increase the separation between the equipment and receiver.

 

* Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

                 * Consult the dealer or an experienced radio/TV technician for help.  
  

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and situations 

that may occur.  It must be understood that common sense and caution are necessary factors in the installation and operation of this fan.

Содержание STK52

Страница 1: ...reparation pg 3 Hanging Bracket Installation pg 3 Fan Assembly pgs 4 5 Wiring pg 6 Canopy Assembly pg 7 Blade Assembly pg 7 Light Kit Assembly pg 8 Assembly of Handheld Remote Control pg 9 Automated L...

Страница 2: ...ld be turned upward and pushed carefully up into the outlet box The wires should be spread apart with the grounded conductor and the equipment grounding conductor on opposite sides of the outlet box W...

Страница 3: ...blade plate in hardware pack 4 pieces q blade 4 pieces r hardware packs page 2 1 Unpacking Your Fan IMPORTANT REMINDER You must use the parts provided with this fan for proper installation and safety...

Страница 4: ...to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet...

Страница 5: ...gram 2 Thread downrod into the motor housing yoke until holes for pin and clip in downrod align with holes in yoke make sure wires do not get twisted Re insert pin and clip that were previously remove...

Страница 6: ...are now ready to hang your fan Grab the fan firmly with two hands Slide downrod through opening in hanging bracket and let hanging ball rest on the hanging bracket Turn the hanging ball slot until it...

Страница 7: ...to fan green black AC IN from breaker box black TO POWER supply black green green bare bare ground ground green bare ground outlet box wall control face plate 12V battery dimmer switch plate DIM ON W...

Страница 8: ...wer tools to assemble the blades If screws are overtightened blades may crack and break Time Saver Washers for blade screws can be set on each blade screw prior to installing blades Locate 12 blade at...

Страница 9: ...rom LED light kit Make sure molex connections snap together completely Refer to diagram 2 Carefully arrange wiring within LED light kit Align holes in LED light kit with holes from post located on fit...

Страница 10: ...to diagram 2 Attach black faceplate to front of wall control press down firmly Refer to diagram 3 Align holes in wall control with posts located on inside of TOP part of remote control cover and pres...

Страница 11: ...power from circuit box and light switch if applicable Test wall control optional installation by locating ON OFF slider switch on wall control then set to the ON position Test light and dimmer functio...

Страница 12: ...ion or use of this product In no case shall the company be liable for any consequential damages for breach of this or any other warranty expressed or implied whatsoever This limitation as to consequen...

Страница 13: ...rta decorativa P g 7 Colocaci n de las aspas P g 7 Instalaci n del juego de luz P g 8 Ensamblaje del control remoto de mano P g 9 Proceso de aprendizaje autom tico El activar el c digo P g 10 Funciona...

Страница 14: ...e que todas las conexiones est n totalmente seguras 7 Despu s de haber terminado todas las conexiones el ctricas los conductores empalmados deben ser volteados para arriba y colocados cuidadosamente d...

Страница 15: ...ra el aspa en paquete de art culos de ferreter a 4 unidades q aspa 4 unidades r paquetes de art culos de ferreter a p gina 2 1 Desempaquetado del ventilador Abrir el empaque cuidadosamente Sacar los a...

Страница 16: ...eglar el alambrado el ctrico los cables en la parte de atr s del soporte y lejos de la abertura del soporte Nota Es muy importante usar los art culos de ferreter a correctos al instalar el soporte de...

Страница 17: ...vija en el tubo con los del cuello asegurarse de que no se tuerzan los cables Volver a introducir el perno y la clavija que se quitaron anteriormente Apretar los tornillos de fijaci n del cuello y la...

Страница 18: ...ta del cable Si el cable se desliza o se reduce el bucle del cable por donde pasa el tornillo hay que ajustar el tama o del bucle Se puede poner el cable en exceso en el rea del techo diagrama 5 ranur...

Страница 19: ...tos as como se muestra en el diagrama al lado Sugerencia Mientras est haciendo la instalaci n el ctrica recordar que los cables no deben impedir el posicionamiento del receptor en el soporte de montaj...

Страница 20: ...astidor del motor tornillos arandelas para fijar el aspa placa del aspa ESTE LADO HACIA ARRIBA etiqueta brazo para el aspa ADVERTENCIA Para reducir el riesgo de lesiones corporales graves NO utilizar...

Страница 21: ...ue se conecten bien las conexiones tipo molex se cierren bien con un clic Referirse al diagrama 2 Con cuidado arreglar los cables dentro del juego de luz LED Alinear los agujeros en el juego de luz LE...

Страница 22: ...l control de pared apretar la tapa fijamente Referirse al diagrama 3 Alinear los agujeros en el control de pared con los postes que se encuentran adentro de la parte SUPERIOR de la cubierta del contro...

Страница 23: ...aci n Regresar la corriente de electricidad en el corta circuitos y el interruptor de la luz si aplica Poner a prueba el control de pared instalaci n opcional localizando el interruptor corredero de A...

Страница 24: ...Soluciones 1 Usar el juego para balancear las aspas incluido en uno de los paquetes de art culos de ferreter a Si no se incluye un juego para balancear las aspas llamar al Servicio al cliente al 1 800...