6. Wiring.

WARNING

: Turn off circuit breakers to current 

fixture from breaker panel and be sure switch is 
turned to the OFF position.

CAUTION

Be sure outlet box is properly grounded or 

that a ground wire (

GREEN

 or Bare) is present.

Make sure all electrical connections comply with Local 
Codes or Ordinances and the National Electrical Code. 
If you are unfamiliar with electrical wiring or if the 
house/building wires are different colors than those 
referred to below, please use a qualified electrician.

Note

Excess lead wire length from the fan can be cut 

to the desired length and then stripped.

When fan is secured in place on the hanging 
bracket, electrical wiring can be made as follows:
Connect 

BLACK

 wire from fan to 

BLACK

 wire from 

ceiling with wire connector provided.
Connect 

WHITE

 wire from fan to 

WHITE

 wire from 

ceiling with wire connector provided.
Connect all 

GROUND 

(

GREEN

) wires together from 

fan to 

BARE

/

GREEN

 wire from ceiling with wire 

connector provided.

* Wrap each wire connector separately with 
electrical tape as an extra safety measure.

[

PLEASE NOTE

: Wall and/or handheld remote 

control must be used for fan to operate. 

If you do 

not

 

wish to use the wall control, please proceed to Section 
7 below to continue with fan installation.

]

To install wall control

, remove existing wall switch. 

Wire one of the

 

wall controls with wire connectors 

provided 

as shown in diagram at right.

*Wrap each wire connector separately with 
electrical tape as an extra safety measure. Gently 
push wires and taped wire connectors into outlet 
box.

Install one 12-volt battery (included) in wall control.

IMPORTANT

: Wall control will not function unless 

battery is installed.

Since this fan does not have a light kit, the dimmer 
switch (labeled 

ON

 and 

D

) has been pre-set to the 

"OFF" position (

D

). If wish to purchase a light kit 

and have dimming capability, please move the 
switch to the "ON" position (

ON

).

Attach wall control to outlet box and secure with 
screws from original wall switch. Attach plate 
(included) to wall control using 2 screws provided 
with the wall control.

wire

connector

black

black

white

white

black supply wire

ground

 (green

or bare)

white supply wire

from ceiling

from fan

ground 
(green or bare)

*

Modifications not approved by the party responsible for compliance 
could void the user's authority to operate the equipment.

*NOTE: This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, if not installed and 
used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures: 
        *      Reorient or relocate the receiving antenna. 
        *      Increase the separation between the equipment and receiver. 
        *      Connect the equipment into an outlet on a circuit different from that to which the

receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

(wiring for fan)

black (OUT to fan)

green

black

(AC IN from

breaker box)

black

(TO POWER supply)

black

green/

green/

bare 

bare 

 ground

 ground

green/

bare 

 ground

outlet box

wall

control

12V battery

dimmer

switch

plate

I

II

IV

VI

VI

I

I

I

I

I

I

V

(wiring for wall control)

Содержание MND72BNK6

Страница 1: ...y pg 7 Switch Housing Assembly pg 7 Handheld Remote Control Assembly pg 8 Automated Learning Process Activating Code pg 9 Remote Wall Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg...

Страница 2: ...than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are n...

Страница 3: ...ece b hanging bracket 1 piece c downrod and hanging ball 1 piece d motor housing 1 piece e switch housing plate 1 piece f switch housing cap 1 piece g yoke cover 1 piece h blade plate 6 pieces i safet...

Страница 4: ...gh point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the ha...

Страница 5: ...n yoke set screws and nuts at top of motor housing Remove pin and clip from motor housing yoke Slide downrod through canopy canopy cover and yoke cover Note Canopy cover must be turned with shiny side...

Страница 6: ...g bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or death Tip Seek the help of another person to hold the stepladder in place and to...

Страница 7: ...tch labeled ON and D has been pre set to the OFF position D If wish to purchase a light kit and have dimming capability please move the switch to the ON position ON Attach wall control to outlet box a...

Страница 8: ...bel on blade indicating THIS SIDE UP Then place blade plate over holes in blade arm making sure to align all 4 holes as shown in drawing at right Partially insert 4 blade attachment screws along with...

Страница 9: ...to the OFF position D If wish to purchase a light kit and have dimming capability please move the switch to the ON position ON Align holes in wall control with posts located on inside of TOP part of r...

Страница 10: ...n the wall control press and hold the fan SET button on the wall control for 5 seconds or until light blinks twice Turn power off again for at least 5 seconds and then turn power back on Within 60 sec...

Страница 11: ...he remote control operates all of the functions of the fan battery has been installed correctly If the wall and or remote controls do does not operate all of the fan functions refer to Troubleshooting...

Страница 12: ...uct for repairs This warranty does not apply when damage from mechanical physical electrical or water abuse results in causing the malfunction Deterioration of finishes or other parts due to time or e...

Страница 13: ...as P g 7 Instalaci n de la caja de encendido P g 7 Ensamblaje del control remoto de mano P g 8 Proceso de aprendizaje autom tico El activar el c digo P g 9 Funcionamiento del control remoto de pared P...

Страница 14: ...l 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tama o correcto de conec...

Страница 15: ...e pared 2 unidades m cubierta del control remoto 1 unidad n placa 1 unidad o tapa 3 unidades p paquetes de art culos de ferreter a p gina 2 Abrir el empaque cuidadosamente Sacar los art culos del emba...

Страница 16: ...las de resorte y las arandelas planas de su nueva o existente caja de salida Si hace la instalaci n en un techo abovedado colocar el soporte de montaje con la abertura dirigida hacia la parte alta del...

Страница 17: ...erno y la clavija del cuello del bastidor del motor Pasar el tubo por la cubierta decorativa la tapa de la cubierta decorativa y la cubierta del cuello Nota Se tiene que voltear la tapa de la cubierta...

Страница 18: ...porte de montaje ADVERTENCIA El no alinear la ranura en la bola que sirve para colgar con la parte saliente del soporte de montaje puede causar lesiones graves o la muerte Sugerencia Solicitar ayuda d...

Страница 19: ...ferencia adversa en la radiocomunicaci n Sin embargo no hay ninguna garant a de que no habr interferencia en una instalaci n en particular Si este equipo s causa interferencia adversa en la recepci n...

Страница 20: ...otor referirse al dibujo al lado Asegurarse de fijarse en la etiqueta en el aspa que indique ESTE LADO HACIA ARRIBA Luego poner la placa para el aspa encima del brazo para el aspa asegur ndose de alin...

Страница 21: ...superior parte inferior cubierta del control remoto diagrama 1 interruptor del reductor de luz control de pared cable cable cable diagrama 2 bater a de 12V I II IV VI III V control de pared cubierta d...

Страница 22: ...hasta que la luz parpadee dos veces Cortar la corriente de nuevo por 5 segundos como m nimo y luego volver a conectar la electricidad Dentro de 60 segundos de haber conectado la electricidad oprimir...

Страница 23: ...TA Si el control de pared control remoto de mano interfiere con otros aparatos activar un c digo nuevo en el control de pared control remoto de mano cortando la corriente primero Repetir las instrucci...

Страница 24: ...funcionamiento Se exenta espec ficamente el deterioro en el acabado u otras partes debido al tiempo o exposici n al aire marino bajo esta garant a Ni Craftmade Ellington ni el fabricante se har n res...

Отзывы: