background image

SAFETY TIPS.

page 1

WARNING

:  To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel 

before you begin the fan installation or before servicing the fan or installing accessories.

1.        

 READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND 

SAVE THESE INSTRUCTIONS.

CAUTION

:  To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

2.         Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and 

ANSI/NFPA 70-1999.  If you are unfamiliar with electrical wiring or if the house/building wires are different 
colors than those referred to in the instructions, please use a qualified electrician.

3.         Make sure you have a location selected for your fan that allows clear space for the blades to rotate, and at least 

ten (10) feet (3.05 meters) of clearance between the floor and the fan blade tips.  The fan should be mounted 
so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or other upright 
structures.

4.         The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 35 

pounds (16 kilograms).  The outlet box must be supported directly by the building structure.  Use only CUL 
(Canada) or UL (USA) listed outlet boxes marked "FOR FAN SUPPORT."

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked "Acceptable 

for Fan Support of 15.9 kg (35 lb) or less," and use the mounting screws provided with the outlet box.  Most outlet 
boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be 
replaced.  Consult a qualified electrician if in doubt.

WARNING

:  To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are 

designed to accept only one 12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 
gauge or there is more than one house wire to connect to the corresponding fan lead wires, consult an electrician for 
the proper size wire connectors to use.

5.         Electrical diagrams are for reference only.  Light kits that are not packed with the fan must be CUL (Canada) 
 

  or UL (USA) listed and marked suitable for use with the model fan you are installing.  Switches must be  CUL 

(Canada) or UL (USA) general use switches.  Refer to the instructions packaged with the light kits and 
switches for proper assembly.

6.         After installation is complete, check that all connections are absolutely secure.
7.         After making electrical connections, spliced conductors should be turned upward and pushed carefully up into 

the outlet box.  The wires should be spread apart with the grounded conductor and the 
equipment-grounding conductor on opposite sides of the outlet box.

WARNING

:  To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device or 

control fan speed with a full range dimmer switch.  [Using a full range dimmer switch to control fan speed will cause a 
loud humming noise from fan.] 

8.        Do not operate the reverse switch until the fan has come to a complete stop. [

Note

: If using remote control  

           with reverse capability, reverse fan blade direction 

only

 when on LOW speed.]

 
9.        Do not insert anything between the fan blades while they are rotating.

WARNING

:  To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.  Do 

not insert objects into the path of the blades.

WARNING

:  To avoid personal injury or damage to the fan and other items, be cautious when working around or 

cleaning the fan.

10.      Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth 

will be suitable for most cleaning.

WARNING

:  To reduce the risk of personal injury, use 

only

 parts provided with this fan.  

The use of parts 

OTHER

 than 

those provided with this fan will void the warranty.

NOTE

:  The important safety precautions and instructions appearing in the manual are not meant to cover all possible 

conditions and situations that may occur.  It must be understood that common sense and caution are necessary 
factors in the installation and operation of this fan.

Содержание MND72BNK6

Страница 1: ...y pg 7 Switch Housing Assembly pg 7 Handheld Remote Control Assembly pg 8 Automated Learning Process Activating Code pg 9 Remote Wall Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg...

Страница 2: ...than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are n...

Страница 3: ...ece b hanging bracket 1 piece c downrod and hanging ball 1 piece d motor housing 1 piece e switch housing plate 1 piece f switch housing cap 1 piece g yoke cover 1 piece h blade plate 6 pieces i safet...

Страница 4: ...gh point of ceiling Arrange electrical wiring around the back of the hanging bracket and away from the bracket opening Note It is very important that you use the proper hardware when installing the ha...

Страница 5: ...n yoke set screws and nuts at top of motor housing Remove pin and clip from motor housing yoke Slide downrod through canopy canopy cover and yoke cover Note Canopy cover must be turned with shiny side...

Страница 6: ...g bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or death Tip Seek the help of another person to hold the stepladder in place and to...

Страница 7: ...tch labeled ON and D has been pre set to the OFF position D If wish to purchase a light kit and have dimming capability please move the switch to the ON position ON Attach wall control to outlet box a...

Страница 8: ...bel on blade indicating THIS SIDE UP Then place blade plate over holes in blade arm making sure to align all 4 holes as shown in drawing at right Partially insert 4 blade attachment screws along with...

Страница 9: ...to the OFF position D If wish to purchase a light kit and have dimming capability please move the switch to the ON position ON Align holes in wall control with posts located on inside of TOP part of r...

Страница 10: ...n the wall control press and hold the fan SET button on the wall control for 5 seconds or until light blinks twice Turn power off again for at least 5 seconds and then turn power back on Within 60 sec...

Страница 11: ...he remote control operates all of the functions of the fan battery has been installed correctly If the wall and or remote controls do does not operate all of the fan functions refer to Troubleshooting...

Страница 12: ...uct for repairs This warranty does not apply when damage from mechanical physical electrical or water abuse results in causing the malfunction Deterioration of finishes or other parts due to time or e...

Страница 13: ...as P g 7 Instalaci n de la caja de encendido P g 7 Ensamblaje del control remoto de mano P g 8 Proceso de aprendizaje autom tico El activar el c digo P g 9 Funcionamiento del control remoto de pared P...

Страница 14: ...l 12 o hay m s de un cable de la casa para conectar a los cables principales del ventilador al cual corresponda cada uno consultar con un electricista para informarse sobre el tama o correcto de conec...

Страница 15: ...e pared 2 unidades m cubierta del control remoto 1 unidad n placa 1 unidad o tapa 3 unidades p paquetes de art culos de ferreter a p gina 2 Abrir el empaque cuidadosamente Sacar los art culos del emba...

Страница 16: ...las de resorte y las arandelas planas de su nueva o existente caja de salida Si hace la instalaci n en un techo abovedado colocar el soporte de montaje con la abertura dirigida hacia la parte alta del...

Страница 17: ...erno y la clavija del cuello del bastidor del motor Pasar el tubo por la cubierta decorativa la tapa de la cubierta decorativa y la cubierta del cuello Nota Se tiene que voltear la tapa de la cubierta...

Страница 18: ...porte de montaje ADVERTENCIA El no alinear la ranura en la bola que sirve para colgar con la parte saliente del soporte de montaje puede causar lesiones graves o la muerte Sugerencia Solicitar ayuda d...

Страница 19: ...ferencia adversa en la radiocomunicaci n Sin embargo no hay ninguna garant a de que no habr interferencia en una instalaci n en particular Si este equipo s causa interferencia adversa en la recepci n...

Страница 20: ...otor referirse al dibujo al lado Asegurarse de fijarse en la etiqueta en el aspa que indique ESTE LADO HACIA ARRIBA Luego poner la placa para el aspa encima del brazo para el aspa asegur ndose de alin...

Страница 21: ...superior parte inferior cubierta del control remoto diagrama 1 interruptor del reductor de luz control de pared cable cable cable diagrama 2 bater a de 12V I II IV VI III V control de pared cubierta d...

Страница 22: ...hasta que la luz parpadee dos veces Cortar la corriente de nuevo por 5 segundos como m nimo y luego volver a conectar la electricidad Dentro de 60 segundos de haber conectado la electricidad oprimir...

Страница 23: ...TA Si el control de pared control remoto de mano interfiere con otros aparatos activar un c digo nuevo en el control de pared control remoto de mano cortando la corriente primero Repetir las instrucci...

Страница 24: ...funcionamiento Se exenta espec ficamente el deterioro en el acabado u otras partes debido al tiempo o exposici n al aire marino bajo esta garant a Ni Craftmade Ellington ni el fabricante se har n res...

Отзывы: