17
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
Be sure power is not connected BEFORE installing door
•
control.
Connect ONLY to 24 VOLT low voltage wires.
•
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
Install door control within sight of garage door, out of reach
•
of children at a minimum height of 5 feet (1.5 m), and away
from ALL moving parts of door.
NEVER permit children to operate or play with door control
•
push buttons or remote control transmitters.
Activate door ONLY when it can be seen clearly, is properly
•
adjusted, and there are no obstructions to door travel.
ALWAYS keep garage door in sight until completely closed.
•
NEVER permit anyone to cross path of closing garage door.
INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of door, at a minimum height of
5 feet (1.5 m) where small children cannot reach, away from
moving parts of door and door hardware. If installing into drywall,
drill 5/32" holes and use the anchors provided. For pre-wired
installations (as in new home construction), it may be mounted to
a single gang box (Figure 2).
Strip 7/16" (11 mm) of insulation from one end of bell wire
1.
and connect to the two screw terminals on back of door
control by color: white wire to 2 and white/red wire to the 1.
Remove cover by gently prying at slot in top of the cover with
2.
a small flat head screwdriver. Fasten with 6ABx1-1/4"
self-tapping screws (drywall installation) or 6-32x1" machine
screws (into gang box) as follows:
Install bottom screw, allowing 1/8" (3 mm) to protrude
•
above wall surface.
Position bottom of door control on screw head and slide
•
down to secure. Adjust screw for snug fit.
Drill and install top screw with care to avoid cracking
•
plastic housing.
Do not overtighten.
Insert top tabs and snap on cover.
•
(For standard installation only)
3.
Run bell wire up wall and
across ceiling to motor unit. Use insulated staples to secure
wire in several places. Do not pierce wire with a staple,
creating a short or open circuit.
Strip 7/16" (11 mm) of insulation from end of bell wire.
4.
Connect bell wire to the quick-connect terminals as follows:
white to white and white/red to red.
NOTE:
When connecting multiple door controls to the
opener, twist same color wires together. Insert wires into
quick-connect holes: white to white and red/white to red.
Position the antenna wire as shown.
5.
Use tacks or staples to permanently attach entrapment
6.
warning label to wall near door control, and manual
release/safety reverse test label in a prominent location on
inside of garage door.
NOTE:
DO NOT connect power and operate opener at this time.
The trolley will travel to the full open position but will not return
to the close position until the sensor beam is connected and
properly aligned.
Drywall Anchors
Insulated
Staples
Screw 6ABx1-1/4"
(std installation)
Screw 6-32x1"
(pre-wired)
HARDWARE SHOWN ACTUAL SIZE
To Replace,
Insert Top
Tabs First
To Remove,
Twist
Here
PRE-WIRED
INSTALLATION
REMOVE & REPLACE COVER
LOCK
24 Volt
2-Conductor
Bell Wire
LIGHT
LIGHT
PREMIUM
CONTROL CONSOLE
Terminal
Screws
(BACK VIEW)
Top
Mounting
Hole
Bottom
Mounting
Hole
WHITE
2
RED
1
Bell
Wire
Strip wire 7/16" (11 mm)
7/16" (11 mm)
Red
Grey
White
Lock
Lighted
Push Button
2-Conductor
Bell Wire
Quick-Connect
Terminals
Antenna
To release or insert wire,
push in tab with screwdriver tip
Door Control
Connections
LOC
K
LIGH
T
Figure 2