HAVING A PROBLEM?
My door will not close and the light bulbs blink on my motor
1.
unit:
The safety reversing sensor must be connected and
aligned correctly before the garage door opener will move in
the down direction.
Verify the safety sensors are properly installed, aligned and
•
free of any obstructions. Refer to
Installation Step 10:
Install The Protector System
®
.
Check diagnostic LED for flashes on the motor unit then
•
refer to the
Diagnostic Chart
on the following page.
My remotes will not activate the door:
2.
Verify your Premium Control Console is not blinking. If it is
•
blinking, deactivate the Lock Mode following the
instructions for
Using the Wall-Mounted Door Control.
Reprogram remotes following the programming
•
instructions. Refer to
Programming
.
If remote will still not activate your door, check diagnostic
•
LED for flashes on motor unit then refer to
Diagnostic Chart
on the following page.
My door reverses for no apparent reason:
3.
Repeat safety
reverse test after adjustments to force or travel limits. The
need for occasional adjustment for the force and limit settings
is normal. Weather conditions in particular can affect door
travel.
Manually check door for balance or any binding problems.
•
Refer to
•
Adjustment Step 2, Adjust the Force.
My door reverses for no apparent reason after fully closing
4.
and touching the floor:
Repeat safety reverse test after
adjustments to force or travel limits. The need for occasional
adjustment for the force and limit settings is normal. Weather
conditions in particular can affect door travel.
Refer to
•
Adjustment Step 1, Adjust the UP and DOWN
Travel Limits.
Decrease down travel by turning down limit
adjustment screw clockwise.
My lights will not turn off when door is open:
5.
The garage door opener is equipped with a security light
•
feature. This feature activates the light on when the safety
sensor beam has been obstructed. Refer to Operation
section; Using the
Wall Mounted Door Control, Light
Feature.
Safety Reversing Sensor
Bell Wire
"Learn"
Button
LED or
Diagnostic
LED
Receiving Eye Safety Reversing
Sensor (Green Indicator Light)
Sending Eye Safety Reversing
Sensor (Amber Indicator Light)
My motor unit hums briefly:
6.
First verify that the trolley is against the stop bolt.
•
Release the door from the opener by pulling the Emergency
•
Release Rope.
Manually bring the door to a closed position.
•
Loosen the chain by adjusting the outer nut 4 to 5 turns.
•
This relieves the tension.
Run the motor unit from the remote control or door control.
•
The trolley should travel towards the door and stop. If the
trolley re-engages with the door, pull the Emergency
Release Rope to disengage.
Decrease the up travel by turning the UP Travel adjustment
•
screw 2 full turns away from the arrow.
Re-tighten the outer nut so the chain is a 1/4" (6 mm)
•
above the base of the rail. (When the door is reconnected
and closed, the chain will sag. This is normal.)
If the trolley does not move away from the bolt, repeat the
•
steps above.