CountyLine CL520CT7 Скачать руководство пользователя страница 6

New Deep Well Convertible Pump Installation 

6

Suction (Larger)

Pipe from Well

To Household

Water System

Well

Head

Drive (Smaller)

Pipe to Well

Venturi

Nozzle

Ejector

Foot Valve

Strainer

5975 0309

Relief 

Valve

Pressure Regulator,

Gauge, and Priming

Plug

4” Or Larger Well

1.  Install the pressure regulator and pressure gauge in the pump body. See 

Figure 1.

2.  Assemble the ejector kit. See Figure 6. Follow the instructions 

included with the kit in order to match the nozzle and venturi to your 
well conditions.

3.  Mount the pump as close to the well as possible.
4.  Connect two pipes (1” drive, 1-1/4” suction) to the ejector and lower 

the ejector into the well until it is five feet from the bottom. It should 
also be at least 10 feet below the well’s water level while the pump is 
running in order to prevent the pump from sucking air.

5.  Install a sanitary well seal and connect the ejector piping to the pump. 

Use steel nipples through the well seal with flexible poly pipe to avoid 
crushing the plastic pipe when tightening the seal.

6.  Support the pipe so that there are no dips or sags in the pipe, so it 

doesn’t strain the pump body, and so that it slopes slightly upward 
from the well to the pump (high spots can cause air pockets which can 
air lock the pump). Seal the suction pipe joints with PTFE pipe thread 
sealant tape or a PTFE-based pipe joint compound. Joints must be air- 
and water-tight. If the suction pipe can suck air, the pump cannot pull 
water from the well.

7.  Run piping from the discharge tee in the tank flange to the household 

piping. The discharge piping must be at least as large as the tank tee. 
Install a relief valve in the discharge pipe capable of passing the entire 
pump flow at 75 psi. Run a pipe from the relief valve to a floor drain or 
some other convenient place to carry off the water.

You have just completed the plumbing for your new pump. Please go to 
Electrical for electrical connections.

2” Well

1.  Install the pressure regulator and pressure gauge in the pump body. See 

Figure 1.

2.  Mount the pump as close to the well as possible.
3.  Assemble ejector kit, well piping, and well head adapter according 

to the instructions provided with the ejector package. See Figure 7. 
Use galvanized drop pipe with turned couplings to allow proper flow. 
Follow the instructions included with the kit in order to match the 
nozzle and venturi to your well conditions.

4.  Run two pipes (one smaller drive pipe, one larger suction pipe) from 

the well to the pump. Support the pipe so that there are no dips or sags 
in the pipe, so it doesn’t strain the pump body, and so that it slopes 
slightly upward from the well to the pump (high spots can cause air 
pockets which can air lock the pump). Seal the suction pipe joints with 
PTFE pipe thread sealant tape or a PTFE-based pipe joint compound. 
Joints must be air- and water-tight. If the suction pipe can suck air, the 
pump cannot pull water from the well.

5.  Run piping from the discharge tee in the tank flange to the household 

piping. The discharge piping must be at least as large as the tank tee. 
Install a relief valve in the discharge pipe capable of passing the entire 
pump flow at 75 psi. Run a pipe from the relief valve to a floor drain or 
some other convenient place to carry off the water.

You have just completed the plumbing for your new pump. Please go to 
Electrical for electrical connections.
NOTICE The ejector kit supplied with your pump tank system will not work 
with a 2” well. You must purchase kit part number FPAP2-P2 and well case 
adapter J216-16A separately.

Figure 6 - 4” and Larger Deep Well

Figure 7 - 2” (Single Pipe) Deep Well

Suction (Larger)

Pipe from Well

To Household

Water System

Relief 

Valve

Pressure Regulator,

Gauge, and Priming

Plug

41

JET  NO

.

J32P-

24

Casing

Adapter

Drive (Smaller)

Pipe to Well

Well Casing

serves as

Drive Pipe

Suction Pipe

Venturi

Nozzle

Ejector

5976 0309

Содержание CL520CT7

Страница 1: ...tallation Operation Parts For further operating installation or maintenance assistance Call 800 535 4950 English Pages 2 13 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento...

Страница 2: ...ing or handling pump If in doubt consult a qualified electrician General Safety Risk of burns Do not touch an operating motor Motors are designed to operate at high temperatures To avoid burns when se...

Страница 3: ...rental applications Sewage Pumps DO NOT return a sewage pump that has been installed to your retail store Contact CountyLine Customer Service Sewage pumps that have seen service and been removed carr...

Страница 4: ...pump body Replace it with a 1 NPT close nipple a 1 x1 x3 4 NPT Tee and a 1 NPT pipe plug Install the pressure gage in the plugged hole in the pump body see Figure 1 3 Install the ejector kit Follow th...

Страница 5: ...r connecting two or three well points to one suction pipe All Shallow Well Installations 6 Install a priming tee priming plug and suction pipe to the pump see Figures 4 and 5 Connect the pipe from the...

Страница 6: ...completed the plumbing for your new pump Please go to Electrical for electrical connections 2 Well 1 Install the pressure regulator and pressure gauge in the pump body See Figure 1 2 Mount the pump a...

Страница 7: ...change the selection 1 2 HP motors are preset at the factory for 115 volts 5 To change the voltage if necessary remove the motor capacitor cover and slide the switch fully to the correct voltage 6 Rei...

Страница 8: ...ation Connection Procedure 1 Connect the ground wire first as shown in Figure 8 The ground wire must be a solid copper wire at least as large as the power supply wires 2 There must be a solid metal co...

Страница 9: ...ping Don t forget to close the control valve each time before you start the pump 5 When pressure has built up and stabilized at about 50 PSI slowly open the control valve see Figure 12 and let the pre...

Страница 10: ...ld pump water in two or three minutes 4 If you don t have water after 2 or 3 minutes stop the pump and remove the fill plugs Refill the pump and piping You may have to repeat this two or three times i...

Страница 11: ...lve and or strainer are buried in sand or mud Raise foot valve and or strainer above bottom of water source Clean foot valve and strainer Water level is too low for shallow well setup to deliver water...

Страница 12: ...eep Well Pump CL520CT7 Part Description Part Number Seal and O Ring Kit RPK 35 Overhaul Kit RPK 205DW Ejector Kit FP520 100 Pump Body Assembly R176 72 Pressure Switch 30 50 TC2151 Pressure Switch Tubi...

Страница 13: ...4 37R 6 3 4 NPT x 1 Hose Barb Adapter 1 24206A004 7 3 4 NPT x 3 4 NPT x 3 4 NPT Street Tee 1 05002A001 8 5 16 18 Flanged Nuts 6 U36 202BT 9 Tank Flange 1 U31 442P Tank Bladder 1 U20 7 10 Tank Body 1 1...

Страница 14: ...e un motor en operaci n Los motores est n dise ados para operar a temperaturas altas Para evitar quemaduras al realizar el servicio a una bomba d jela enfriar por 20 minutos despu s de apagarla No per...

Страница 15: ...productos utilizados en aplicaciones comerciales o de alquiler Bombas cloacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al...

Страница 16: ...bajar en ella o en el motor 1 Drene y retire la bomba vieja Revise las condiciones de la tuber a que no tenga xido sarro etc y reempl cela si es necesario 2 Saque el regulador de pres on del cuerpo de...

Страница 17: ...o 4 Coloque la bomba lo m s cerca posible del pozo vea la Figura 5 5 Si un punto filtrante no suministra suficiente agua considere la posibilidad de conectar dos o tres puntos filtrantes a una tuber a...

Страница 18: ...informaci n sobres las conexiones el ctricas Pozo de 2 1 Instale el regulador de presi n y el man metro en el cuerpo de la bomba Vea la Figura 1 2 Monte la bomba tan cerca del pozo como sea posible 3...

Страница 19: ...de 1 2 HP vienen pre configurados de f brica para 115 voltios 5 Para cambiar el voltaje si es necesario saque la cubierta del condensador del motor y deslice el conmutador totalmente para corregir el...

Страница 20: ...necte el alambre de puesta a tierra primero seg n se ilustra en la Figura 8 El alambre de puesta a tierra debe ser un alambre de cobre s lido por lo menos tan grande como los alambres de suministro de...

Страница 21: ...lvula de control y vuelva a llenar la bomba y la tuber a Posiblemente tendr que repetir esto dos o tres veces para sacar todo el aire atrapado en la tuber a No olvide cerrar la v lvula de control cad...

Страница 22: ...a colocar todos los tapones de llenado 3 Enci ndala Arranque la bomba La bomba debe bombear agua despu s de 2 o 3 minutos 4 Si no tiene agua despu s de 2 o 3 minutos pare la bomba y retire todos los t...

Страница 23: ...el colector est n enterrados en arena o en lodo Eleve la v lvula de pie y o el colector por encima del fondo de la fuente de agua Limpie la v lvula de pie y el colector El nivel de agua es demasiado b...

Страница 24: ...4 NPT 2 tapones de 1 2 NPT Unidad del cuerpo de la bomba pozo poco profundo 2 6 13 14 15 tapones de 1 4 NPT 2 tapones de 1 2 NPT Man stato 3 Juego de tuber a del man stato 6 3 7 Ref Descripci n Cant...

Страница 25: ...ervadura de manguera de 3 4 NPT x 1 1 24206A004 7 T macho hembra de 3 4 NPT x 3 4 NPT x 3 4 NPT 1 05002A001 8 Tuercas embridadas de 5 16 18 6 U36 202BT 9 Brida del tanque 1 U31 442P C mara del tanque...

Страница 26: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 27: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 28: ......

Отзывы: