![Cornelius FCB - 2 Flavor Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/cornelius/fcb-2-flavor/fcb-2-flavor_service-manual_2667818058.webp)
Pinnacle 2 and 4 Flavor Service Manual
F
OAM
P
ACK
R
EPLACEMENT
:
1.
Disconnect the power to the unit. Remove back middle panel (4 screws) and side panels (3 screw each).
2.
Turn OFF the blendonator valve.
3.
Drain the cylinder of the faulty foam pack by opening the dispensing valve. When only CO
2
comes out, turn
the cylinder product supply valve off. Relieve CO
2
pressure by opening the faceplate pressure relief valve.
4.
Remove the cylinder face plate (4 nuts).
5.
Remove beater bar and scrapper blades.
6.
Use the magnet puller tool (p/n 560003662) that comes with the unit to remove the magnet.
NOTE: Sufficient force must be used to break the magnet lose from the end of the cylinder.
CAUTION
— The magnet is very strong and heavy. Be careful not to pinch hands and fingers
between the magnet and a steel object.
WARNING
— Strong Magnetic Field.
Person wearing pacemaker, implanted cardioverter defibrillator, or other implanted medical device
may be effected by the magnetic field and must keep the magnet at 6 or more inches from the
device. The magnetic field can affect operation of these devices which may cause bodily injury or
death.
If disruption of device occurs or operation is adversely effected, immediately move the victim far away from
magnet and seek medical assistance.
7.
Disconnect product supply line. Disconnect wire harness. Remove foam insulation. Remove screw in
center of stator assembly. Unbend the index tabs and remove end cap.
8.
Remove the stator assembly from the cylinder (4 nuts).
9.
Reclaim refrigerant.
10. Remove 4 bolts and pry off stator plate.
11. Remove front splash panel and drip tray mounting panel.
12. Remove 2 nuts on bottom of foam pack front and rear
mounting bars.
FIGURE 70
FIGURE 71
13. Remove refrigeration line insulation from back of foam pack and remove thermistors (sensors) from
refrigeration lines. Unsweat fittings from the back of the foam pack. Lift the foam pack out the front of the
unit.
14. Reverse the procedure to install new foam pack. Replace the dryer. Evacuate and recharge the system.
Underside of
Foam pack
Back of Unit
Slot in
Frame
Face plate screws (2)
© 2003-2014, Cornelius Inc.
- 54 -
Publication Number: 560007298SER
Содержание FCB - 2 Flavor