Pinnacle 2 and 4 Flavor Service Manual
Menu 9 - VISC DISPLAY (Actual Cylinder Viscosity)
This menu displays the actual viscosity value for each cylinder. The smaller the number the lower the vis-
cosity (thinner product).
VISC DISPLAY Menu Button Descriptions:
#1 - BACK . . . . . . . go back to the previous menu
The table below identifies the maximum and minimum viscosity values for specific viscosity settings. For
example, with a viscosity setting of 2, the system calls for refrigeration when the viscosity drops below 43.
Refrigeration continues until the viscosity reaches 60 when leveling begins.
NOTE: There is a 2 minute timer to prevent the compressor from short cycling. This timer is can-
celed out by a Blendonator actuation.
FIGURE 17
Viscosity Setting
Maximum Viscosity
Value
Minimum Viscosity
Value
1
50
36
2
60
43
3
70
58
4
80
68
5
90
78
6
100
86
7
110
96
8
120
106
9
130
116
Actual Viscosity
Reading
Cylinder
Numbers
© 2003-2014, Cornelius Inc.
- 24 -
Publication Number: 560007298SER