Pinnacle 2 and 4 Flavor Service Manual
3. Close barrel # 1 freeze cylinder shutoff valve (see below).
4. Turn blendonator #1 OFF (from the BLENDONATOR menu) to prevent more product from entering the
blendonator.
5. Place container under barrel # 1 dispensing valve. Open the valve and dispense all product from the
freeze cylinder and the blendonator. As product level lowers in the freeze cylinder partially close the valve
to avoid spurting.
6. Disconnect bag-in-box from barrel # 1.
7. Wash the system by completing the following steps:
• Use a clean 5-gallon pail (bag-in-box system) filled with a solution of household liquid detergent
and warm water. Mix approximately 1 ounce of household liquid detergent per gallon of warm water.
• Connect the sanitizing fitting (p/n cc 28688) to the bag-in-box connector. Put the connector in the
bucket of wash water.
• Turn barrel # 1 blendonator ON (from BLENDONATOR menu) to fill blendonator.
• Fill barrel # 1 with washing solution by repeatedly pulling and releasing the faceplate relief valve
until solution comes out.
• Open the dispensing valve until solution flows from the valve, then close the valve.
• Open blendonator sample valve (see FIGURE 4) until solution flows from the valve, then close the
valve.
• Place barrel # 1 in MOTOR mode (from ON/OFF/MOTOR menu) to start barrel # 1 beater. Allow
beater to operate for 5–minutes, then place barrel # 1 in OFF mode (from ON/OFF/MOTOR menu) to
stop the beater.
FIGURE 3
FIGURE 4
Freeze
Cylinder
Shutoff Valve
BRIX Sample
Valves
© 2003-2014, Cornelius Inc.
- 9 -
Publication Number: 560007298SER