Pinnacle 2 and 4 Flavor Service Manual
A
DJUSTMENTS
Water, Syrup, & CO
2
Regulator Settings
P
INNACLE
C
ONTROL
S
YSTEM
Control System Overview
The Pinnacle uses a control system that monitors the major systems and components of the machine.
Temperatures and pressures are monitored, and pumps, valves and the refrigeration system are man-
aged by the control system to provide a consistently high quality product with optimal efficiency.
The control system is pre-programmed at the factory to perform the tasks necessary to keep the Pinnacle
operating correctly. In addition to controlling the Pinnacle, the control system keeps track of the diagnos-
tic information used when adjusting and/or repairing the machine.
The control system needs to be accessed in the following situations:
• Installing the Pinnacle,
• Checking performance,
• Servicing/repairing the machine,
• Checking for error messages.
The control system is accessed with the control panel located behind the lighted merchandiser. There
are 2 levels of access to the control panel: 1 used by the operator for normal operations and 1 used by
qualified service technicians for installation and service functions. The service functions can be secured
(locked out) so that the operator will not have access to them. See the Security Lockout Function section
under menu 15 for more information.
Regulator Settings
CO
2
source (at unit)
60 psi
CO
2
Blendonator
22 - 28 psi
Water source (at unit) (minimum)
25 psi flowing
Syrup source (at unit)
60 psi
FIGURE 5
Control Panel
Display
© 2003-2014, Cornelius Inc.
- 12 -
Publication Number: 560007298SER
Содержание FCB - 2 Flavor
Страница 75: ......