background image

TigoStarter K6 

User Manual

 

 

Copyright © 2020 CoreTigo Ltd.

 

 

 
 

Page 

24

 of 

32

 

 

 

3.5.

 

Show Revisions 

 

This option will display the SW and HW revision info.  
The W-Master revisions are displayed first and following it the connected W-Device revisions.  
The date in the parenthesis indicates the compilation time of the revision.

 

 
 
 
 
 
 
 
 

Figure 22 - Show revisions

 

3.6.

 

Debug 

 

This option will display the SW and HW revision info.The debug menu allows to easily use some of the debug 
features implemented in the CoreTigo IO-Link wireless stack.  
 
 
 
 
 
 
 
 
 

Figure 23 - Debug Menu 

 

Show Analog Display - 

When a W-Device is configured to analog mode, selecting this option will enter an 

analog display mode, in which the analog value reported by the W-Device is displayed.  

 

AL Read - 

This Function allows ISDU Read from the Operational Wports.  

Will return the value after entering the wanted port, index & subindex.  

 

AL Write - 

This Function allows ISDU write to Operational Wports.  

Will write the value given entering the wanted port, index & subindex and Value.  

 

Set PDOut - 

This Function allows sending Process Data Out to selected operational Wport.  

Used for Actuator mode.  

 

Get PDIn 

- This Function allows reading Process Data In from selected operational Wport. Used for 

Sensor mode.  

  

3.7.

 

Flash Internal MCU 

This Function allows to flash the CT264-0083-01 STM32L151 MCU using the ST-Micro bootloader application 
over UART. When this option is chosen and confirmed, the Nucleo-F767ZI will reset the STM32L151 on the W-
Master evaluation board and set the Boot0 pin to 1 and reset again, this action will cause the STM32L151 MCU to 
boot with the bootloader application. The first action is then to initiate a communication over UART with the 
bootloader application, then the STM32L151 Flash will be erased and rewritten with the image which can be found 
in 

Examples\IOLW_Basics_Example\Src

.  

Once the flashing is done the W-Master application must be reset.

 

 

Содержание TigoStarter K6

Страница 1: ...TigoStarter K6 User Manual Copyright 2020 CoreTigo Ltd Page 1 of 32 TigoStarter K6 IOLW Master Development Revision 1 0 USER GUIDE...

Страница 2: ...ent 13 2 3 2 1 TigoMaster 2TS Development HW setup 13 2 3 2 2 TigoMaster 2TS Evaluation SW use 14 2 4 Connect the TigoAir Device 16 2 4 1 TigoMaster E2 Device Development HW setup 16 2 4 2 TigoMaster...

Страница 3: ...gure 13 TigoBridge LEDs labeling 18 Figure 14 Putty configuration window 19 Figure 15 Master UI Menu first image 20 Figure 16 Setting menu 20 Figure 17 Scan result display example 21 Figure 18 W Port...

Страница 4: ...ce HW Hardware IF Interface IOLW IO Link Wireless LED Light Emitting Diode PD Process Data SW Software UART Universal Asynchronous Receiver Transmitter W Device IO Link Wireless Device W Master IO Lin...

Страница 5: ...e components This user guide will guide you through 1 Setup IO Link Master 2TS IO Link Device TigoAir wirelessly 2 Get Familiar with the TigoEngine SW engineering tools to evaluate IO Link Wireless of...

Страница 6: ...2 54mm pitch JTAG cable to a slimmer 2x5 0 05 1 27mm pitch SWD 1 16 Pin to U Art 1 AC DC WALL MOUNT ADAPTER 5V 6W 1 1 5M LONG POWER CABLE 1 Test Plugs Test Jacks quick connect black sheated straight T...

Страница 7: ...nection of an IO Link Wireless Master Device to Evaluate IO Link Wireless Enables simple connection of a single IO Link or digital sensor actuator directly to the TigoBridge thus turning those devices...

Страница 8: ...vices as described further down in this document o STM32CubeProgrammer enables fast programming using the ST Link debugger provided in the starting kit o CP2108 USB to UART Bridge driver from https ww...

Страница 9: ...control with TigoEngine configuration tool 2 Development Connected to PC via the provided Application processor NUCLEO F767ZI control via Master Menu Figure 3 2TS Product Description TigoMaster 2TS c...

Страница 10: ...ted with the TigoMaster 2TS Upon installation use the TigoEngine software engineering tool for configuring IO Link Wireless master and devices Reference TigoEngine Installation Guide for TigoMaster 2T...

Страница 11: ...ted to PC TigoEngine User Interface 1 Masters View Masters view is intended for connecting a new W Master to the TigoEngine and keeping a record of configured W Masters TigoEngine supports multiple W...

Страница 12: ...Click on Scan Tab to open area use scan button on the right side of the view Figure 6 TigoEngine Scan 3 Locate the UID of device needed for pair Hexadecimal representation 4 Select the required W Devi...

Страница 13: ...reference for quick and easy ramp up to develop a TigoMaster application Reference TigoMaster SMI API SW Guide for TigoMaster 2TS 2 3 2 1 TigoMaster 2TS Development HW setup The Nucleo board s need to...

Страница 14: ...sequence required to flash new Application developed Open the STM32 ST LINK Utility and connect to your device Click on Target Program Verify Browse to CoreTigo_SDK_Release_XX_YY_ZZZZ SDK_Release_Tig...

Страница 15: ...erence example With Reference Application Menu it is possible to configure Control and monitor Wireless IO Link link Mainly o Via Setting menu Scan Pair Unpair and monitor Link quality o Via Master Co...

Страница 16: ...t using an A to mini B USB cable 2 4 1 TigoMaster E2 Device Development HW setup Figure 11 TigoAir E2 2 4 2 TigoMaster E2 Device Development SW setup To flash the MCU use the ST Link debugger JTAG to...

Страница 17: ...ith an IP67 enclosure The TigoBridge converts IO Link to IO Link Wireless The TigoBridge includes an internal antenna and two M12 connectors for data and power TigoBridge is a device that connects a w...

Страница 18: ...s LED will alternate between magenta and yellow 5 Plug TigoBridge to an IO Link device sensor actuator Note if TigoBridge cannot connect directly to the device you may use an M12 cable Once connection...

Страница 19: ...Master USB connection mentioned previously will also give you access to its UI which is addressable as a Serial COM port at a Baud Rate of 115200 Make sure the Nucleo F767ZI USB marked in Figure 34 i...

Страница 20: ...r using the reset button You should now see the following image Figure 16 Master UI Menu first image Use the option numbers to navigate in the menu for example press 1 and then Enter to enter Settings...

Страница 21: ...sec and return to the menu for more info on the scan process refer to the IO Link Wireless Master API Guide 1 Figure 18 Scan result display example 2 Show Scan Result this function prints the last sc...

Страница 22: ...eset reboot the master will load the last stored configuration and attempt to connect with the configured devices 7 Disable Port this option allows you to remove a wireless port that no longer exist a...

Страница 23: ...ameter refer to the IO Link Wireless Master API Guide 1 3 Set Max Retry all Wports this option changes the max_retry parameter and essentially contains the maximum number of retries for a transmission...

Страница 24: ...t index subindex AL Write This Function allows ISDU write to Operational Wports Will write the value given entering the wanted port index subindex and Value Set PDOut This Function allows sending Proc...

Страница 25: ...cy tests Figure 24 Test Tab 4 1 Test 1 IO Link Wireless Latency In CoreTigo s Latency reference the Cycle time parameter is controlled directly via the max_retry configuration field Set in port config...

Страница 26: ...t2 IO Link PER Test PDIn The test triggers PDin Device to Master Test output Arrived Missing PER Figure 26 IO Link Wireless PDIn PER 4 3 Test3 IO Link PER Test PDout The test triggers PDout Master to...

Страница 27: ...T PERMITTED UNDER APPLICABLE LAW IF YOU DO NOT AGREE TO BE BOUND BY THIS AGREEMENT PLEASE DO NOT DOWNLOAD INSTALL OR USE THE PRODUCT THE PRODUCT MAY BE USED SOLELY FOR YOUR PERSONAL NON COMMERCIAL PUR...

Страница 28: ...Payment Terms Company agrees to compensate CoreTigo for the Evaluation in the amount as set forth in the quotation attached hereto and or associated and referencing this Agreement which shall be paid...

Страница 29: ...RIGHTS 11 High Risk Activities Company hereby acknowledges that the Product is not fault tolerant and is not designed manufactured or intended for use or resale as on line control equipment in hazardo...

Страница 30: ...cessary safeguards affording the Confidential Information at least the same level of protection that it affords its own information of similar importance to prevent the disclosure of such Confidential...

Страница 31: ...y the other party shall certify in writing to the other its compliance with the terms of this Section 17 4 17 5 Without derogating from any of the terms set forth above Company further agrees that fol...

Страница 32: ...acknowledgement are null void and of no effect A waiver of any provision will not constitute a continuing waiver of such provision or a waiver of any other provision Failure by either party to demand...

Отзывы: