GARDiS Controller  

And Extension Modules 

 

User Manual 

UM0120 Issue 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание GARDiS 1

Страница 1: ...GARDiS Controller And Extension Modules User Manual UM0120 Issue 1 ...

Страница 2: ...th it may not be used for any purpose other than that for which it is supplied nor shall any part of it be reproduced without the prior written consent of TDSi Microsoft and Windows are registered trademarks of Microsoft Corporation All other brands and product names are trademarks or registered trademarks of their respective owners Cautions and Notes The following symbols are used in this guide C...

Страница 3: ...h and RTE Egress Buttons 9 8 Connecting the Power Supply 10 9 Connection POE Power Supply 10 10 Connecting a GARDiS Controller to the Ethernet Network 11 Set Date and Time 12 11 Extending the System 13 License Dongle 13 GARDiS 4 Extension Module 14 11 2 1 Connecting to Master Controller 15 11 2 2 Adding the Module using the Embedded Web Server 15 GARDiS I O Extension Module 16 11 3 1 Connecting to...

Страница 4: ... readers for the Reverse LRC protocol In Out Readers Limited functionality is available with this configuration Licensing dongle is required to allow more doors on the system Wireless IP Locks is limited to 10 doors 2 Information and Recommendations In accordance with the European directive UTE C00 200 incorporating directives 2004 108 CE GARDIS complies with the following standards NF EN 50081 1 ...

Страница 5: ... optional Features Max 5000 Credentials Doors 1 2 or 4 doors Readers Up to 2 TDSi readers per reader channel in a read in read out configuration Alternatively 1 reader per door equipped with industry standard clock data Wiegand multiformat or RS 485 output formats Inputs 1 per door Additional available with I O Module Outputs Control Relay 1 A 12V 1A 24v 1 used per installed door GARDIS 1 2 Output...

Страница 6: ...efore allowing a person entry OR can be used to check a sensor such as vehicle present break glass sensor before allowing entry Ethernet Network connection1 Ground Power Ground Test power Auto protection Normally closed Common Normally open Normally closed Common Normally open Power Ground Clock Data 1 A Data Data 0 B LED Ground Egress RTE Door Sense Conditional Entry Clock Data 1 A Data 0 B LED G...

Страница 7: ...onditional O P This section has 2 outputs An open drain and a relay These outputs can be set from the cause and effect function For example activate the relay for 10 seconds if a person switches on a light ...

Страница 8: ...ce 150m 30m in RS485 Cable Type 0 6mm Recommended 6 Core Belden 9730v Belden 9503 OS6C24 Alpha 5096 BICC H8124 Screened Alarm Cable Screen Recommended Stranded core If using an external power supply for your readers ensure to connect the different grounds to the controller Do not install cables from readers to controllers near high voltage or high current cables Each reader can be set to a differe...

Страница 9: ...7 6 Connecting Lock s Fail Safe Electric Strike and Door Magnet Connecting Standard Fail Secure Electric Strike Power Supply 12V 0V Power Supply 12V 0V Lock suppressor Lock suppressor ...

Страница 10: ...h lock see above Four suitable suppressors 1N4007 are provided with each controller When using an external power supply for the locks the lock suppressor must be connected as shown on the wiring diagram above For maximum reliability we recommend the use of separate power supplies for locks If using one supply for the controller and the lock s it controls no issue should occur provided the supply h...

Страница 11: ...9 7 Connecting Tamper Switch and RTE Egress Buttons Tamper switch Door 1 Egress Button Door 1 Door 1 Contact ...

Страница 12: ...the source PSE Power sourcing equipment In the event of loss of the PoE source the green LED light will turn off Power will continue to be delivered if a backup battery is connected to the system When installing the controller with an SLA Sealed Lead Acid backup battery the ferrite supplied should be fitted to the red and black leads with a single turn and secured with a cable tie PoE Source 802 3...

Страница 13: ...tated below IP Address 192 168 2 150 Subnet Mask 255 255 255 0 To set a different IP Address you must first connect to the unit using the default values and login to the embedded web server Launch a web browser and enter the IP Address of the unit The default logins are below Login admin Password Located on the label of the unit Crossover Cable if required Straight cable Straight cable ...

Страница 14: ...Date and Time Set the time on the unit to ensure events are reported at the correct time Log in to the unit Go to Site Configuration and select the Date from the calendar Enter the current time Click Set Time ...

Страница 15: ... unit The available extensions include the GARDiS 4 and GARDiS I O The extension units may be a mixture of both types of extensions and use the RS485 to daisy chain the units together A maximum of 10 extension units may be used License Dongle The dongle will determine the total number of units permitted in the system The image below shows how to insert the purchased dongle ...

Страница 16: ...170 x 119 x 40 mm Weight 282 g Operating Environment 0 C to 50 C 0 95 Relative Humidity non condensing Power Input 9 to 14 VDC 1A without PSU 100 240Vac 50 60Hz 1 8A max PSU Output PSU 1 x 13 8Vdc 3A and 1 x 13 8Vdc 2A Features Doors 4 doors Readers Up to 2 TDSi readers per door in a read in read out configuration Alternatively 1 reader per door equipped with industry standard clock data Wiegand m...

Страница 17: ...m Cable Type 0 6mm SYT recommended Do not install cables near high voltage or high current cables Use the same pair for the A and B terminal blocks 11 2 2 Adding the Module using the Embedded Web Server Connect to the embedded webserver logging into the unit click Site Configuration Extensions then click add Key A B ...

Страница 18: ...lowing diagram shows how to connect the GARDiS I O module to a master controller TDSi Part No GARDiS IO EXT 5002 6006 Dimensions 157 x 120 x 30 mm Weight 200 g Operating Environment 20 C to 50 C 0 95 Relative Humidity non condensing Power Input 9 to 14 VDC 1A without PSU Output 1A 12V 1A 24V Features Inputs 8 Outputs 8 Communications RS485 to daisy chain to master controller unit ...

Страница 19: ...g Information 2 Conductors 2 pairs recommended Maximum distance 750m Cable Type 0 6mm SYT recommended Do not install cables near high voltage or high current cables Use the same pair for the A and B terminal blocks 11 3 2 Connecting an Egress Button ...

Страница 20: ...te use module s GND as common For all outputs ensure you use supplied lock suppressors if electromagnetic devices are installed Electric strike door magnet relay etc Each module input can be independently used in 2 or 4 state modes These modes can be configured from the embedded web server menu To adjust the detection level if using another resistor value each input can be calibrated as well as ad...

Страница 21: ...onds 4 Release the switch SW2 Restore factory network settings 1 Turn off power 2 Press switch down while returning power to unit 3 Setting the network mode a For static IP mode Release the switch at the first flashing of the extension bus blue LED approximately 5 seconds b For DHCP mode Release the switch after second flashing of the extension bus blue LED Please Note GARDiS 4 Door Controller wil...

Страница 22: ...Do you have any technical questions Contact our free technical support TDSi UK T 44 0 1202 723 535 E support tdsi co uk TDSi Export T 33 0 1 58 84 20 90 E info tdsi france com ...