![background image](http://html1.mh-extra.com/html/tdsi/gardis-1/gardis-1_user-manual_826000012.webp)
10
8.
Connecting the Power Supply
Part Number: 5002-6050 Metal Case + PSU Single
9.
Connection POE Power Supply
Part Number: 5002-6051 Metal case + POE Single
It is recommended the 802.3bt is used as standard as the source equipment to the PoE
module as this will provide the required current to operate controller and readers. When
installing the system, observe the manufacturer’s instructions for the source PSE (Power
sourcing equipment).
In the event of loss of the PoE source, the green LED light will turn off. Power will continue
to be delivered if a backup battery is connected to the system. When installing the
controller with an SLA (Sealed Lead Acid) backup battery, the ferrite supplied should be
fitted to the red and black leads with a single turn and secured with a cable tie.
PoE Source
802.3bt
Phase
Neutral
Earth
12V / 3A output
(Door equipment)
12V / 2A output
(Controller)
Battery
+12V
0V
+12V
0V
+12V
0V
12V / 3A output
(Controller)
+12V
0V
Ethernet into GARDiS
master controller
+12V
0V
Battery