TigoStarter K6
User Manual
Copyright © 2020 CoreTigo Ltd.
Page
18
of
32
Installation
:
1.
Plug 24VDC power supply to TigoBridge M12 power connector via M12 cable.
2.
The Power LED will light up green. If not, please verify the power connection.
3.
Once power supply is connected, a reset cycle occurs. The reset cycle’s duration is
a few seconds and displays a red à green à blue color sequence.
4.
Once the reset cycle is over, the status LED will alternate between magenta and yellow.
5.
Plug TigoBridge to an IO-Link device (sensor/actuator). Note, if TigoBridge cannot connect directly to
the device, you may use an M12 cable. Once connection is done successfully the Status LED will
alternate between Magenta and Green.
6.
Open TigoEngine, scan the network for the IO-Link Wireless TigoBridge.
2.5.1.
TigoBridge LEDs indication
•
The RGB LED on the TigoBridge use to indicate both the IOL master and the IOLW Device status
•
The duty cycle is 50%, toggling between the two above
•
The following table explains the RGB LED functionality:
Figure 14 - TigoBridge LEDs & labeling