VCX-4402-E Installation and Operating Instructions
Page 25
The com port selection is configurable. However, the default setting should be adequate for normal
operation.
Default:
Com port 1 - 5002
Com port 2 – 5004
Example Command:
COM1PORT 5010
(sets com port 1 to port 5010)
COM1RS422, COM2RS422 <0|1>
The com port data-format is configurable. The parameter is “0” or “1”, where “1” enables RS-422
and “0” enables RS-232 format.
Default: 0 (RS-232)
Example Command:
COM1RS422 0
(sets com port 1 for RS-232)
COMM PORT COMMAND – FURTHER EXAMPLES
The following examples set up com port 1:
COM1 1
– Enable com port 1
COM1BAUD 9600
– Set com port 1 baud rate to 9600
COM1RS422 1
– Set com port 1 mode to RS422
COM1PORT 5002
– Set com port 1 port to 5002
COM1PARITY E
– Set com port 1 parity to even
COM1IP 192.168.0.10
– Set destination address for data to 192.168.0.10
COMxTCP <0|1>
1= Use TCP, 0=Use UDP
COMxSERVER <0|1>
1 = server, 0 = client
OSD COMMANDS (On Screen Display)
These permit the configuration of the On-Screen-Display(OSD) properties of the encoder. This
section is for labeling the video stream.
OSD <1…5> <label text>
This command permits up to five lines of text to be configured for display with the outgoing
video stream. The text lines must be assigned from 1 to 5 in order and unassigned lines between assigned
lines are not permitted. All five lines need not be assigned text strings.
Example
osd 1 This is the first line of text.
osd 2 This is the second.
This is the first line of text.
This is the second