VCX-4402-E Installation and Operating Instructions
Page 8
Having used either of these methods, the encoder is ready to receive configuration
commands.
Main unit configuration
The VCX-4402-E units incorporate support MPEG-4 encoding from two different input
channels. It is important the operator understand this to be able to configure the unit properly. All
commands follow this simple format:
(command<space>parameter<enter>)
From the command prompt, the operator may view the current configuration by entering the
“
display
” command. This will dump the entire configuration status for the selected encoder. Remember
there are three encoders in one unit. Enter the following configuration for each of the encoder channels.
Take note the IP address must be of valid encoders on the network. The IP addresses below are just an
example. Locate two MPEG4 encoders.
Connection Configuration
ip 192.168.5.150 (use a valid IP on your network)
ipmask 255.255.240.0
name CoreTec Encoder
default
com1 1
com1ip 192.168.5.151 (IP address of the decoder that is sending sub-channel commands)
com1tcp 1 (assume a universal decoder)
com1server 1
com1timeout 20
com1baud 38400
com1rs422 1
MPEG4 Configuration (encoder 1)
The MPEG4 encoder requires the following parameters be configured to your network:
encoder 1
enable 1
videoip 239.5.5.150 (use a valid IP on your network)
res 1/2
bitrate 1800
port 4568
videoin 1
MPEG4 Configuration (encoder 2)
The MPEG2 encoder requires the following parameters be configured to your network:
encoder 2
enable 1
videoip 239.5.5.151 (use a valid IP on your network)
port 4570
bitrate 1800
res 1/2
fps 30