Carbon brushes 

Make sure to have carbon brushes inspected every 12 months and replaced if necessary by a certified expert. 
 

Drilling with water cooling  – Water connection  

The  drilling  machine  is  equipped  with  a  water  tap,  which  includes  a  ‘Gardena’  connection.  Make  sure  that  the  core  drill  is 
sufficiently  cooled  and  that  the  slurry  is  properly  discharged.  The  maximum  permitted  water  pressure  is  3  bars.  Always  use 
clean  water  to  enlarge  the  life  span  of  the  internal  water  seals.  In  case  of  leakage,  the  drilling  machine  has  to  be checked 

IMMEDIATELY by a certified  mechanical expert.  
 

Operating instructions 

If  drilling  is  done  by  hand,  initially  the  drill  should  never  be  applied  perpendicular  to  the  material  (the  drill  may  start 
‘spinning’). Spinning is prevented by drilling the first centimeter / 0,5 inch at an angle of 30 degrees.  Then the drill can be 

slowly brought to the desired position. 

 

 

 
GEAR 1 

è

 450 RPM only with drill rig

 

 

Tips 

 

Diamond drills which are not precisely circular cause extra burden to the bearings and the cogs. 

 

Drill carefully and sensitively. Always avoid overloading. 

 

Do not lift/move drill machine by the cable  

 

If the switches, cable, plug or machine case  is  damaged, switch off the machine immediately and  have it repaired by a 
certified expert. 

 

Switch on the machine only if the diamond drill can turn freely. 

 

When changing the diamond drill, always use 2 spanners . Never use a hammer as this may damage the cogs. 

 
Recycling 

 

According  to  the  European  regulation  2002/96/EC,  CORE  Powertools  is  responsible  to  recycle  old  electric  drill 
motors. 

You are therefore requested to return old CORE Powertools electric drill motors to your local reseller. 

Guarantee 

For  the  CX20  S3,  a guarantee period  of  12 months  applies  from the  moment  of deliver.  Guarantee  claims must be  shown by 
submission  of  purchase  invoice.  The  guarantee  includes  the  repair  of  defects  which  have  occurred  and  can  be  linked  by  to 
material or manufacturing faults. 
 

Not covered by guarantee: 

 

Defects or damages which have arisen due to incorrect use or connection.  

 

Machine overload. 

 

When maintenance has been carried out incorrectly or badly. 

 

Information in the manual has not been properly followed. 

 

The machine is used by unqualified persons. 

 

If the machine is used for purposes for which it is unsuitable. 

 

The machine is repaired using unoriginal parts. 

 

If the machine encryption is damaged or deleted. 

 

If defects are caused by fire, damp and/or transport. 

Содержание CX20 S3

Страница 1: ...NL Gebruikershandleiding Pagina 2 ENG Operating Instructions Page 6 F Manuel d utilisation Page 10 D Bedienungsanleitung Seite 14 E Manual P gina 18 I Manuale Pagina 22 03 06...

Страница 2: ...is een ge soleerde diamantkernboormachine voor NAT gebruik voor toepassing in combinatie met diamantkernboren voor het boren van gaten in steenachtige materialen en beton De boormachine kan zowel gebr...

Страница 3: ...t De RESET knop dient opnieuw te worden ingedrukt Let op De PRCD en het elektriciteitssnoer mogen nimmer in contact komen met water Controleer voor ingebruikname de PRCD door op de TEST knop te drukke...

Страница 4: ...achinebehuizing is beschadigd de machine meteen uitschakelen en laten repareren door de erkende vakman Schakel de machine alleen in als de diamantboor vrij kan draaien Tijdens het wisselen van de diam...

Страница 5: ...het stopcontact te trekken Bescherm de kabel tegen hitte olie en scherpe randen 10 Zorg voor een veilige houding Vermijd een abnormale lichaamshouding en zorg voor een stabiel evenwicht 11 Onderhoudt...

Страница 6: ...ns has to be followed Technical Description The CX20 S3 is an insulated diamond core drilling machine for WET use in combination with diamond core drilling for drilling holes in stone materials and co...

Страница 7: ...PRCD is switched off the RESET button must be pressed again Note The PRCD and the electrical cable should never come in contact with water Check the PRCD by pressing the TEST button before use Never u...

Страница 8: ...machine by the cable If the switches cable plug or machine case is damaged switch off the machine immediately and have it repaired by a certified expert Switch on the machine only if the diamond drill...

Страница 9: ...use the cable to pull the plug out Protect the cable against heat oil and sharp edges 10 Ensure safe posture Avoid abnormal physical postures and ensure a stable balance 11 Look after tool carefully...

Страница 10: ...ice peuvent tre chang es Allgemeine preventive Ma regeln und die notwendigen Sicherheitsvorschriften m ssen befolgt werden Description technique Le mod le CX20 S3 est une carotteuse isol e pour les ut...

Страница 11: ...otection Il prot ge l utilisateur de l lectrocution D s que la carotteuse est branch e le PRCD se met en marche le bouton RESET en vert En cas d interruption le PRCD se met sur OFF le bouton vert RESE...

Страница 12: ...atement et doit tre r par e par un r parateur agr e Allumer la carotteuse d s lors que la couronne diamant e peut tourner librement Assurez vous qu en cas de changement de couronne la t te soit propre...

Страница 13: ...anormales Ayez toujours une station verticale stable et conservez toujours votre quilibre 11 Entretenez soigneusement vos outils lectriques Veillez ce qu ils soient bien aff t s et propres afin de pou...

Страница 14: ...notwendigen Sicherheitsvorschriften m ssen befolgt werden Technische Beschreibung Der CX20 S3 ist eine isolierte Diamantkernbohrmaschine f r den Na einsatz In Verbindung mit Diamantbohrkronen wird si...

Страница 15: ...cherheitsschalter zum Personenschutz welcher den Anwender vor Elektroschl ge sch tzt Dieser beinhaltet sowohl FI Schutz als auch Unterspannungsausl sung Der PRCD ist nach dem Einstecken des Netzstecke...

Страница 16: ...Werkzeug nicht am Kabel und ben tzen Sie es nicht um den Stecker aus der Steckdose zu ziehen Wenn der Schalter Kabel Stecker oder das Maschinegeh use besch digt ist schalten Sie den Maschine direkt a...

Страница 17: ...annten Fachmann erneuern Kontrollieren Sie Verl ngerungskabel regelm ig und ersetzen Sie sie wenn sie besch digt sind Halten Sie Handgriffe trocken und frei von l und Fett 12 Ziehen Sie den Netzstecke...

Страница 18: ...ci n t cnica La CX20 S3 es una m quina de perforaci n con diamante Core dotada de aislamiento para la realizaci n de trabajos en H MEDO en combinaci n con brocas diamantadas apta para perforar agujero...

Страница 19: ...Si el PRCD est apagado el bot n RESET ha de pulsarse de nuevo Nota El PRCD y el cable el ctrico no han de entrar nunca en contacto con agua Compruebe el PRCD pulsando el bot n TEST antes de usar No u...

Страница 20: ...icadeza Evite siempre la sobrecarga No levante o mueva la m quina de perforar tirando del cable Si los interruptores el cable el enchufe o la caja de la m quina est n en mal estado desconecte la m qui...

Страница 21: ...eja el cable del calor aceites y bordes cortantes 30 Adopte una postura segura Evite adoptar posturas f sicas inc modas y aseg rese de mantener el equilibrio 31 Cuide las herramientas Mantenga las her...

Страница 22: ...eventive generali e le istruzioni di sicurezza allegate Descrizione tecnica CX20 S3 una perforatrice con anima in diamante isolato per utilizzo AD ACQUA in combinazione con punte con anima in diamante...

Страница 23: ...Il PRCD e il cavo elettrico non devono mai entrare in contatto con l acqua Controllate il PRCD premendo il tasto TEST prima dell uso Evitate sempre di utilizzare la perforatrice con anima in diamante...

Страница 24: ...ico Evitate di spostare sollevare la perforatrice prendendola per il cavo Se gli interruttori il cavo la spina o l involucro della macchina sono danneggiati spegnete la macchina immediatamente e fatel...

Страница 25: ...cavo e non tirate il cavo per estrarre la spina Proteggete il cavo da vapore olio e spigoli 50 Accertatevi di tenere una postura corretta Evitate le posture anomale e accertatevi di trovarvi in equil...

Страница 26: ...ss dieses Produkt gem ss den EG Richtlinien 89 336 EWG 98 37 EWG 73 23 EWG 2002 96 EWG bereinstimmt und folgende Normen bzw Normendokumente angewendet wurden EN 55014 1 EN 61029 1 EN 61000 3 2 EN 6074...

Отзывы: