ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
9
6
Keypad Ribbon
Cable
Locate (3) oval head screws
and insert through the
escutcheon and thread
into the outside escutcheon.
Ground
Wire
Thumb Turn
Micro Switch
Installation of Inside Escutcheon
NOTE: Connectors go on only one way. Do not offset connector and be sure they are completely seated.
1. Connect ground wire to ground terminal, keypad ribbon cable connector to controller, and lock body
harness to motor connector. If you have a thumb turn, connect the male thumb turn switch connector
to the female thumb turn switch connector.
2. Align thumb turn to the vertical position.
3. Feed excess lock body harness wire back into the mortise of the door between the door cavity and
lock body, making sure no excess wire enters the cylinder hole of the lock body. (see diagram page 8)
Push excess keypad ribbon cable into the ribbon cable hole.
NOTE: For RF Technology versions refer to Section 5 to install through bolt screws.
Controller
Female Thumb Turn
Switch Connector
Male Thumb Turn
Switch Connector
Thumb Turn
C A U T I O N
DOOR MUST REMAIN OPEN
DURING INSTALLATION.
USE DOOR STOP.
Thumb Turn Male Switch
Connector - for non
thumb turn mortise locks
the thumb turn male
switch connector may
be placed in the space
below the controller and
remain disconnected
1
Motor Connector
Ground Terminal
Red & Black
Wires
Keypad Harness (ribbon cable)
Remote Power
Connector
(M35 Remote Power
Wiring Harness also
available as part
No. 793F069)
Lock Body Harness
Lock Body
Harness
Gasket
GASKET APPLICATION:
Peel off the adhesive protective paper
from gasket. Feed Trim assembly motor
harness through gasket opening as shown
and firmly press gasket to escutcheon,
aligning edge of gasket with the edge of
the escutcheon.
Inside
of door
4) Installation Instructions