ElectroLynx® is a registered trademark of ASSA ABLOY Inc.
Copyright © 2014 Corbin Russwin, Inc. All rights reserved.
Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
18
7.6) M35 Power/Remote Unlocking Harness
1.
®
ElectroLynx System Wiring Instructions (refer to Fig. 1 and Fig. 3)
a.
Look for the mating part on ASSA ABLOY doors and frames. Then plug in all
connectors as shown in Fig. 3 during product installation.
b.
Hard wire 784 power supply as shown.
2.
®
Non-ElectroLynx System Wiring Instructions (refer to Fig. 1 and Fig. 3)
a.
Cut the 8-pin connector off the Power/Remote Unlocking harness and hard wire
®
to non-ElectroLynx door harness. Remote power requires three conductors and
remote unlock requires two conductors.
b.
Hard wire door harness to power transfer device.
c.
Hard wire 784 power supply as shown.
Installation:
Fig. 3
Power/Remote Unlocking
®
ElectroLynx Wiring System
QC8 Electric Hinge
with 8-pin connectors,
8 wires and pigtail harness
®
ElectroLynx Door Harness
with 8 & 4-pin connectors.
Harness location is
dependent on door type.
Unlocking
1
2
3
4
5
6
7
8
Red
Black
White
Orange
Blue
Brown
Y
ellow
Green
(-)
REX
REX
Data Out
Data In
RTS
(EGND)
+9
REX Input
Connect to
Device.
Only used in
combination
with the M861
Option.
It may be left
unconnected.
M35
Power/Remote
Harness
6 AA batteries MUST be removed from
controller if 784 Power supply is used.
Door
Outside
Escutcheon
Inside
Escutcheon
Ground Tab
Remote Power and
REX Connector TB2
Motor
Connector
TB1
Black, 1
Red, 2
White, 3
Green, 4
Orange, 5
Blue, 6
Brown, 7
Yellow, 8
784
9VDC
Power Supply
120 VAC L/N/G
EGND
+9 VDC
-9 VDC
C
NO
Normally Open
momentary switch
(Remote unlock
- REX option)
7) ML20800 TCAC2 Hardwiring Instructions