Xenus

 

PLUS

2-Axis CANopen

XP2

Rev 01

 

Test conditions: Wye connected load: 2 mH line-line. Ambient temperature = 25° C. Power input = 230 Vac, 60 Hz, 1 Ø

MoDEl

 

  

XP2-230-20 

OuTPuT CuRRENT (EACH AxIS)

 

Peak Current 

 

20 (14) 

 

Adc (Arms, sinusoidal)

 

 

Peak time 

 

 

s

 

 

Continuous current (Note 1) 

 

10 (7) 

 

Adc (Arms, sinusoidal)

inPUT PoWER 

 

Mains voltage, phase, frequency 

 

100~240 

 

Vac, ±10%, 1 Ø or 3 Ø, 47~63 Hz

 

 

Mains current 

 

20 

  

Arms 

 

+24 Vdc  Control power 

 

+20 to +32 Vdc, 500 mA max 

 

Required for operation

DIGITAl CONTROl 

 

Digital Control loops 

Current, velocity, position. 100% digital loop control

 

 

Sampling r

ate (time) 

Current loop: 16 kHz (62.5 µs), Velocity & position loops: 4 kHz (250 µs)

 

 

Bus voltage compensation 

Changes in bus or mains voltage do not affect bandwidth 

 

Minimum load inductance 

200 µH line-line

COMMAND INPuTS (NOTE: DIGITAl INPuT FuNCTIONS ARE PROGRAMMABlE)

  Distributed Control Modes 

 

CANopen 

Position, Velocity, Torque (Profile & Interpolated modes), Homing

 

  Stand-alone mode 

 

Analog torque, velocity, position reference 

±10 Vdc, 14 bit resolution 

Dedicated differential analog input

 

 

Digital position reference 

Pulse/Direction, CW/CCW 

Stepper commands (2 MHz maximum rate)

 

 

 

quad A/B Encoder 

2 M line/sec, 8 Mcount/sec (after quadrature)

 

 

Digital torque & velocity reference 

PWM , Polarity 

PWM = 0% - 100%, Polarity = 1/0

 

 

 

PWM 50% 

PWM = 50% ±50%, no polarity signal required

 

 

 

PWM frequency range 

1 kHz minimum, 100 kHz maximum

 

 

 

PWM minimum pulse width 

220 ns 

 

Indexing 

up to 32 sequences can be launched from inputs or ASCII commands.

 

 

Camming 

up to 10 CAM tables can be stored in flash memory

 

 

ASCii 

RS-232, 9600~115,200 Baud, 3-wire, RJ-12 connector

DIGITAl INPuTS

number 22 

 

[IN1,11] 

Digital, Schmitt trigger, 1 µs RC filter, 24 Vdc compatible, programmable pull-up/down to +5 Vdc/ground, 

 

 

 

Vt+ = 2.5~3.5 Vdc, VT- = 1.3~2.2 Vdc, VH = 0.7~1.5 Vdc

 

 

[IN21, 22] 

Same specs as IN1 & IN11, but with fixed pull-up to +5 Vdc

 

 

[IN2~5,12~15] 

Programmable as single-ended or differential pairs, 100 ns RC filter, 5 Vdc max, 

 

 

 

10 k

 programmable pull-up/down per input to +5 Vdc/ground, 

 

 

 

SE: Vin-lO ≤ 2.3 Vdc, Vin-HI ≥ 2.7 Vdc, VH = 45 mV typ, DIFF: Vin-lO ≤ 200 mVdc, Vin-HI ≥ 200 mVdc, VH = 45 mV typ,

 

 

[IN6~9,16~19] 

Opto-isolated, single-ended, ±15~30 Vdc compatible, bi-polar, 2 groups of 4 with common return for each group

 

 

 

Rated impulse ≥ 800 V, Vin-lO ≤ 6.0 Vdc, Vin-HI ≥ 10.0 Vdc, Input current ±3.6 mA @ ±24 Vdc, typical

 

 

[IN10,20] 

Motor overtemp signals on feedback connectors, , Schmitt trigger, 24 Vdc compatible

 

 

 

330 µs RC filter, 4.99k pullup to +5 Vdc,  Vt+ = 2.5~3.5 Vdc, VT- = 1.3~2.2 Vdc, VH = 0.7~1.5 Vdc

ANAlOG INPuTS

 number 

 

[AIN1~2] 

Differential, ±10 Vdc, 5 k

 input impedance, 14-bit resolution 

 

[AIN3~4] 

Single-ended, motor temperature sensor, 4.99 k

 pulled-up to +5 Vdc, 12-bit resolution

SAFE TORquE OFF (STO)

Function 

PWM outputs are inactive and current to the motor will not be possible when the STo function is asserted 

Standard 

Designed to iEC-61508-1, iEC-61508-2, iEC-61800-5-2, iSo-13849-1 

Safety integrity level 

Sil 3, Category 3, Performance level d 

inputs 

2 two-terminal: STo-in1+,STo-in1-, STo-in2+, STo-in2- 

Type 

Opto-isolators, 24V compatible, Vin-lO ≤ 6.0 Vdc or open, Vin-HI ≥ 15.0 Vdc,

 

Input current (typical)  STO-IN1: 9.0 mA, STO-IN2: 4.5 mA

 

Response time 

2 ms from Vin ≤6.0 Vdc to interruption of energy supplied to motor

 

Reference 

Complete information and specifications are in the Xenus Plus 2-Axis STO Manual

DIGITAl OuTPuTS

 number 

 

 

[OuT1~5] 

Opto-isolated Darlingtons, 20 mA max, 24 V tolerant, collector & emitter connections

 

 

[OuT6~7] 

Motor brake control: opto-isolated, current-sinking with flyback diode to +24 Vdc, 1 Adc max

RS-232 PoRT

 

Signals 

RxD, TxD, Gnd in 6-position, 4-contact RJ-12 style modular connector

 

 

Mode 

Full-duplex, DTE serial communication port for drive setup and control, 9,600 to 115,200 baud 

 

Protocol 

Binary and ASCii formats

CAn PoRT

 Signals 

CANH, CANl, Gnd in 8-position dual RJ-45 style modular connector, wired as per CAN Cia DR-303-1, V1.1

 

 

Format 

CAN V2.0b physical layer for high-speed connections compliant

 

 

Data 

CANopen Device Profile DSP-402

 

 

Address selection 

16 position rotary switch on front panel with 3 additional address bits available as 

 

 

 digital inputs or programmable to flash memory (7-bit addressing, 127 nodes per CAN network)

STATUS inDiCAToR lEDS

 

Drive Status 

Bicolor lED, drive status indicated by color, and blinking or non-blinking condition

 

 

CAN Status 

Bicolor lED, status of CAN bus indicated by color and blink codes to CAN Indicator Specification 303-3

5V OuTPuT

 

Number 

4, two on the feedback connectors (J10, J11), two on the control connector (J12) for the A and B multi-mode ports

 

 

Ratings (each) 

+5 Vdc @ 500 mA, thermal and overload protected

general specIfIcatIons

Содержание Xenus Plus XP2 Series

Страница 1: ...ded For safety critical applications redundant power stage enable inputs can be employed Control Modes Indexer Point to Point PVT Camming Gearing Position Velocity Torque Command Interface CANopen ASC...

Страница 2: ...ated single ended 15 30 Vdc compatible bi polar 2 groups of 4 with common return for each group Rated impulse 800 V Vin LO 6 0 Vdc Vin HI 10 0 Vdc Input current 3 6 mA 24 Vdc typical IN10 20 Motor ove...

Страница 3: ...onal Safety IEC 61508 1 IEC 61508 2 EN ISO 13849 1 EN ISO 13849 2 IEC 61800 5 2 see The Xenus Plus Dual Axis STO Manual for further detail Electrical Safety Directive 2006 95 EC Low Voltage IEC 61800...

Страница 4: ...tion counter 29 bit absolute position data status data for encoder operating conditions and errors BiSS B C MA MA X X SL SL S S signals 4 wire clock output from XP2 data returned from encoder Digital...

Страница 5: ...t drives can be daisy chained and controlled with a single connection to the user s CAN interface A CAN terminator should be placed in the last drive in the chain The XP2 NK connector kit provides a D...

Страница 6: ...grammed using CME 2 a control program can use the ASCII Interface to Enable the amplifier in Programmed Position mode Home the axis Issue a series of move commands while monitoring position velocity a...

Страница 7: ...he upper and lower devices in the PWM outputs from being operated by the digital control core This provides a positive OFF capability that cannot be overridden by the control firmware or associated ha...

Страница 8: ...ferential inputs have 121 W line terminators Single ended pulse Direction Single ended CU CD QUAD a b ENCODER SINGLE ENDED differential CU CD differential pulse Direction QUAD a b ENCODER DIFFERENTIAL...

Страница 9: ...ey Controls 20 Dan Road Canton MA 02021 USA Tel 781 828 8090 Fax 781 828 6547 Tech Support E mail sales copleycontrols com Web http www copleycontrols com Page 9 of 34 RoHS XenusPLUS 2 Axis CANopen XP...

Страница 10: ...8 6547 Tech Support E mail sales copleycontrols com Web http www copleycontrols com Page 10 of 34 RoHS XenusPLUS 2 Axis CANopen XP2 Rev 01 HS Inputs IN1 2 24 Vdc max PLC outputs are frequently current...

Страница 11: ...are two groups of four inputs each with its own common terminal Grounding the common terminal configures the inputs to work with current sourcing outputs from controllers like PLC s When the common te...

Страница 12: ...Road Canton MA 02021 USA Tel 781 828 8090 Fax 781 828 6547 Tech Support E mail sales copleycontrols com Web http www copleycontrols com Page 12 of 34 RoHS XenusPLUS 2 Axis CANopen XP2 Rev 01 The analo...

Страница 13: ...Support E mail sales copleycontrols com Web http www copleycontrols com Page 13 of 34 RoHS XenusPLUS 2 Axis CANopen XP2 Rev 01 isolated brake outputs Brake outputs Opto isolated Flyback diodes for ind...

Страница 14: ...or both is open This will produce the same fault condition as a short circuit across the inputs Low differential voltage detection This is possible with very long cable runs and a fault will occur if...

Страница 15: ...ling of the encoder data occurs at the current loop frequency 16 kHz The number of encoder data bits and counts per motor revolution are programmable The hardware bus consists of two signals SCLK and...

Страница 16: ...forms that drive the motor phase coils Cable should be sized for the continuous current rating of the motor Motor cabling should use twisted shielded conductors for CE compliance and to minimize PWM n...

Страница 17: ...n MA 02021 USA Tel 781 828 8090 Fax 781 828 6547 Tech Support E mail sales copleycontrols com Web http www copleycontrols com Page 17 of 34 RoHS XenusPLUS 2 Axis CANopen XP2 Rev 01 The multi mode port...

Страница 18: ...addition to eliminating Y cabling where the motor feedback cable has to split to connect to both controller and motor the buffered outputs reduce loading on the feedback cable that could occur if the...

Страница 19: ...IN9 5 24V 100p 10k 10k 74HC14 INx 5V 33n 10k 4 99k 74HC2G14 INx 5V Copley Controls 20 Dan Road Canton MA 02021 USA Tel 781 828 8090 Fax 781 828 6547 Tech Support E mail sales copleycontrols com Web h...

Страница 20: ...2 15 8 IN15 J12v 30 inputs with programmable pull up Down CMe2 screen for inputs IN11 in20 input data IN11 IN22 IN20 IN12 15 HI LO definitions inputs IN16 19 are optically isolated and work from posit...

Страница 21: ...gnal Pins OUT1 J9 19 OUT1 J9 10 OUT2 J9 20 OUT2 J9 11 OUT3 J9 21 OUT3 J9 12 OUT4 J9 22 OUT4 J9 13 Input State Condition OUT1 4 HI Output transistor is ON current flows LO Output transistor is OFF no c...

Страница 22: ...to move Brake state is NOT Active CME2 Default Setting for Brake Outputs OUT6 7 is Brake Active HI Active Brake is holding motor shaft i e the Brake is Active Motor cannot move No current flows in co...

Страница 23: ...22 Sgnd Enc A Enc A Enc B Enc B Enc X Enc X 5V Out 5 TEMP SENSOR 7 Signal Gnd Motemp 4 3 2 1 Mot U Mot V Mot W Shield J3 J4 J5 2 3 1 24V Brake B 4 5 24V Brake A Gnd 24 Vdc Axis A Brake Axis B Brake Xe...

Страница 24: ...x J10 J11 IN21 22 Sgnd Enc Sin Enc Sin Enc Cos Enc Cos Enc Index Enc Index 5V Out TEMP SENSOR 7 Signal Gnd Motemp 4 3 2 1 Mot U Mot V Mot W Shield J3 J4 J5 2 3 1 24V Brake B 4 5 24V Brake A Gnd 24 Vdc...

Страница 25: ...J10 J11 IN21 22 Sgnd Rlvr Sin Rlvr Sin Rlvr Cos Rlvr Cos Rlvr Ref Rlvr Ref 5V Out 5 TEMP SENSOR 7 Signal Gnd Motemp 4 3 2 1 Mot U Mot V Mot W Shield J3 J4 J5 2 3 1 24V Brake B 4 5 24V Brake A Gnd 24...

Страница 26: ...IN2 9 STO Gnd 5 STO IN1 S1 S2 J9 FEEDBACK A ISOLATED I O FEEDBACK B J10 J11 24 24 A BRK B BRK 24V RTN J6 SAFETY J5 BRAKE MOTOR B MOTOR A REGEN POWER U V W H L U V W J3 J4 J1 J2 L1 L2 L3 4 min Copley...

Страница 27: ...ID AMP NETWORK A B ERR L A RUN L A S1 S2 J9 FEEDBACK A ISOLATED I O FEEDBACK B J10 J11 24 24 A BRK B BRK 24V RTN U V W H L U V W L1 L2 L3 4 min Copley Controls 20 Dan Road Canton MA 02021 USA Tel 781...

Страница 28: ...TO IN1 S1 S2 J9 FEEDBACK A ISOLATED I O FEEDBACK B J10 J11 24 24 A BRK B BRK 24V RTN J6 SAFETY J5 BRAKE MOTOR B MOTOR A REGEN POWER U V W H L U V W J3 J4 J1 J2 L1 L2 L3 4 min Copley Controls 20 Dan Ro...

Страница 29: ...J9 FEEDBACK A ISOLATED I O FEEDBACK B J10 J11 24 24 A BRK B BRK 24V RTN U V W H L U V W L1 L2 L3 4 min Copley Controls 20 Dan Road Canton MA 02021 USA Tel 781 828 8090 Fax 781 828 6547 Tech Support E...

Страница 30: ...that connect to J3 1 J4 1 These cables should be of the same gauge as the other motor phase cables For CE compliance and operator safety the drive heatplate should be earthed to the equipment frame A...

Страница 31: ...shielding performance power regen brake connections Notes 1 Items marked with CE are required for standards conformance 2 In the end product installation a UL RC Recognized Component SPD Surge Protect...

Страница 32: ...e remains at earth potential and eliminates a shock hazard that could occur of the chassis were allowed to float to the potential of the mains While this connection keeps the heatplate at earth potent...

Страница 33: ...02 8 301 210 85 8 860 225 04 5 417 137 6 9 240 234 7 2 384 60 55 3 588 91 13 093 2 36 0 19 4 75 5 62 142 7 Copley Controls 20 Dan Road Canton MA 02021 USA Tel 781 828 8090 Fax 781 828 6547 Tech Suppo...

Страница 34: ...male solder cup Norcomp 180 044 103L001 1 Backshell DB 44 44 Pin RoHS metallized Norcomp 979 025 020r121 1 J9 I O Connector high density DA 26F 26 position female solder cup Norcomp 180 026 203L001 2...

Отзывы: