Menvier40/100
Page 1
1. Introduction
The Menvier40 and Menvier100 are control
units for hybrid wired/wirefree alarm
systems intended for domestic, commercial
or industrial use.
Both control units have identical hardware,
but the Menvier40 can handle up to 40
zones, while the Menvier100 can handle up
to 100 zones. See the
Menvier40/100/300
Engineering Guide
for a list of other
software differences.
The Menvier40/100 control unit comprises a
steel case containing the control unit PCB
(printed circuit board), power supply and
space for a backup battery (not supplied).
The control unit PCB provides terminals for
a single bus. The bus allows you to connect
up to 20 peripheral devices to the
Menvier40 and up to 45 peripheral devices
to the Menvier100. The bus cabling uses
standard four wire alarm cable. The
peripheral devices can be any mixture of
keypads, zone expanders (for wireless or
wired detectors) or remote power supplies.
The control unit PCB also provides a range
of connectors for outputs, communicators,
and up to 10 FSL (Fully Supervised Loop),
10 2-wire Closed Circuit Loop (CCL) or five
4-wire CC (Closed Circuit) zones.
The control unit uses i-kp01 keypads with
software revision 3.02 and above. The
keypads allow end users to set and unset
the system, and the installer to configure
the control unit. The i-kp01 keypad also
contains an integral proximity tag reader,
allowing end users to control the system
without having to remember access codes.
A range of wireless peripherals is available
for operation with the wireless expanders.
These include a door contact/universal
transmitter, a passive infra red detector,
smoke detector, external siren, 4 button
remote control, and remote radio keypad.
This control unit is designed and approved
to be used as part of a Security Grade 3
system. The control unit is also approved to
operate as part of a Security Grade 2
system. If you install any radio devices this
will limit approval to Security Grade 2 in
the ward in which they are used.
Communications
The control unit contains a built-in ATS2
communicator, allowing it to comply with
EN50131 at Security Grade 2.
The control unit also provides sockets for
an add-on communication module. The
available modules are:
i-sd02
(ATS2)
A speech dialler and public
switched telephone network
(PSTN) module that allows the
control unit to send recorded
speech messages and report
alarm information using
standard protocols such as
Fast Format, SIA and Contact
ID. This module also allows
remote maintenance.
i-dig02
(ATS2)
A switched telephone network
(PSTN) module that allows the
control unit to report alarm
information using standard
protocols such as Fast Format,
SIA and Contact ID. This
module also allows remote
maintenance.
i-gsm02
(ATS2)
A GSM module that allows
alarm reporting, speech
messaging and SMS text
messaging over the mobile
phone network.
Note: Fitting a plug on module disables the
internal communicato.
The control unit also provides outputs that
can be used to fit a “plug by”
communicator.
To be approved at Security Grade 3 use the
plug-by communicator outputs to connect
the control unit to an ATS4 communicator.
Level Setting or Ward based system
The control unit offers two basic ways of
behaving as an alarm system:
Part Setting
. In a Part Setting system the
control unit can set in one of four ways:
either Full set or three varieties of Part Set.
In Full set the control unit pays attention to
all detectors. In each of the three Part Sets
the control unit ignores detectors that do
not have the appropriate Part Set attribute.
Ward Based System
. In a ward based
system the Menvier40 provides the
equivalent of 5, smaller, independent alarm
systems, called “wards”. The Menvier100
provides 10 wards. You can allocate any