
Menvier40/100
Installation
Page 15
Mains Connection
Figure 22 shows the mains connection.
Connect to a suitable supply using a double
pole disconnect (isolation) device in
accordance with EN60950-1.
Caution:
Do not apply power at this
point.
Anchor the mains cable with a strain-relief
tie. There is a eye located near the mains
cable entry hole for this purpose.
L
N
T250mA 250V
230V ~50Hz 170mA
Figure 22 Mains Connection
Step 6. Connect Wired
Zones
The control unit and the wired expander
connectors can be used for either four wire
Closed Circuit (CC) detectors, two wire CC
detectors, or two wire Fully Supervised
Loop (FSL) detectors.
Four Wire Closed Circuit Connections
Figure 23 shows the wiring for four wire
CCL zones on the control unit. Figure 24
shows the wiring for four wire CCL zones on
the wired expander. Note that the
connections are different on the expander
compared to the control unit.
Figure 23 Control Unit CCL Zone Wiring
Wired Expander
Z0
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z8
Z9
Alarm Zone 1
Alarm Zone 2
Alarm Zone 0
Tamper Zone 1
Tamper Zone 2
Tamper Zone 0
Figure 24 Wired Expander CCL Zone Wiring
Two-Wire Closed Circuit Connections
With version 4.02 software you can connect
two-wire CCL detectors to each pair of zone
terminals. To specify the zone wiring type
use the
Installer Menu – System Options – Wire
Zone Type
option and select “2-wire CC”.
If required you can use one pair of zone
terminals as a common tamper, provided
you program that zone with the type
“Tamper” from the Installer Menu.
Fully Supervised Loop Connections
Figure 25 shows the wiring connections for
FSL zones on the control unit. Note that the
resistance values shown are examples.
Содержание Menvier 100
Страница 1: ...MENVIER SECURITY...
Страница 4: ...Menvier40 100 Page iv This page is intentionally blank...