Technical Specification
Menvier40/100
Page 32
communicator fitted the requirement drops
to 30 hours.
This means that all the devices powered by
the backup battery, including the control
unit and at least one keypad, should
together draw no more in total than an
average of 570mA over a 30 hour standby
time. Note that for Security Grade 3 the
control unit must use a plug-by
communicator, which may have its own
power supply.
For Security Grade 2 the required battery
standby time is 12 hours. However, the
total average current available over 12
hours from the 17Ah battery is limited by
the power supply to 750mA. (The current is
limited to 750mA because when mains is
present the 1.5A power supply reserves
750mA to recharge batteries, leaving
750mA available to supply the system.)
The table below shows the current
consumption of the control unit and each
device that can be fitted to it.
CIE power
requirement:
120mA min.
200mA max
i-kp01 power
requirement:
30mA (normal/idle)
45mA (backlight low)
65mA (backlight
high)
Wired Expander
requirement
20mA max quiescent.
300mA in alarm if
sounder connected.
Radio Expander
requirement
40mA max quiescent
320mA in alarm if
sounder connected.
Battery charging
requirement:
750mA per battery
(recharge to 80%
within 24 hrs)
Plug-on
Communicator
power requirement:
i-sd02 or i-dig02:
20mA quiescent
50mA max
Plug-on
Communicator
power requirement
i-gsm02:
150mA quiescent
and max.
Plug-by
Communicator pins
require:
3mA each when
active.
10 FSL zones
20mA
5 CCL zones
30mA
12V Bus output
voltage range :
10±0.5V to 13.8V
12V Aux output
voltage range:
10±0.5V to 13.8V
12V Bell output
voltage range
10±0.5V to 13.8V
Max p-to-p ripple
voltage:
0.5V
Standby Battery:
12V, 17Ah sealed
lead acid (not
supplied).
„Low battery‟ fault
at:
< 12V
Aux power output
fault at:
< 9V
Deep discharge
protection at:
10±0.5V
Overvoltage
protection trigger
voltage
15.8±1.0V
Standby time:
See “Power
Availability” on page
8.
Electromagnetic
Compatibility
Immunity
Conforms to EN50130-4.
Emissions
Conforms to EN61000-6-3.
Outputs
Panel: O/P 1
Voltage free, single pole
relay contacts rated 24VDC
@ 1A.
Panel:
O/P 2 - 3
Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
Plug-by O/P
1-16
Open collector transistor
+12VDC when inactive, 0V
when active, 50mA max.
LS 1
(loudspeaker)
Min impedance 16 Ohm per
output, current
consumption = 280mA in
alarm.
Expander:
Outputs
Open collector transistor,
+12VDC when inactive, 0V
when active. 500mA max.
Note: The current is limited
by the amount available
from the power supply
driving the expander.
Sounder Volume Levels (at 1m)
i-kp01 (at max volume)
70dB
Expander sounders
70dB
Expander 16 Ohm loudspeaker
93dB
Fuses
The control unit has a replaceable T250mA
mains fuse.
Electrical Safety
Conforms to EN60950-1.