Menvier40/100
Installation
Page 23
followed by the words “Please wait...”
for several seconds while the control
unit scans the bus. When the control
unit has finished scanning the bus the
keypads show:
2. Press and hold keys A and
simultaneously on the keypad that you
wish to use for initial programming.
NOTE: Hold the keys down for at
least three seconds.
After a short pause the keypad gives a
confirmation tone. The display briefly
shows the bus address of the keypad. If
there are no other keypads connected to
the bus it should be “b1-d51”(bus 1
device 51). Keypads take bus device
addresses 51 upwards.
The keypad display then shows:
3. Press A or B to select either a Ward
based system or a Part Setting system.
The display shows:
4. Press
or
to show the Security
Grades available, for example:
5. Press
to select the security grade you
intend to use for the system.
The display shows:
6. Press
or
to show the range of zone
wiring types available, for example:
7. Press
to select the wiring type you
intend to use for the wired zones.
Note: This initial choice fixes the wiring
type for the control unit and any attached
wired expanders. If you wish to use a
different wiring type on the expanders then
use
Installer Menu – Detectors/Devices –
Wired Expander
after the initial power up to
change the wiring type for each expander.
The display shows:
Note that the alert LEDs round the
navigation key glow red. This is because
the control unit lid is off and the tamper
is active.
8. Press
.
The display shows:
9. Press
.
The display shows:
10. Press
.
The display shows:
11. Press
.
The display shows:
At this point you must make the control
unit allocate an address to each of the
connected bus devices, as follows:
12. Go to each bus device. You can visit the
devices in any order, but if you visit
them in the order you want their
address numbers to appear then it will
make subsequent programming easier.
The control unit assigns the next free
bus address to a bus device when you
make the device request a bus address.
For keypads:
Hold down keys A and
until the
display shows a bus and device number.
For example the second keypad would
be:
For expanders:
Open the lid (to make sure that the
tamper switch is open) and hold down
the addressing button (item 3 on
Figures 9 and 10 ). When you do so the
control unit assigns the next free
address to that expander. The expander
gives a double “beep” confirmation tone
and shows its assigned address on the
two-digit LED display. Replace the lid.
NOTE:
1. DO NOT request a bus address from two
different devices at the same time.
2. EXP-R30 expanders take three bus
addresses.
13. When you have visited all the connected
bus devices, go back to the keypad and
press
. The display shows:
14. Replace the control unit lid, making
sure that the lid tamper closes.