4. Maintenance
The control unit should be inspected once
per year. At each inspection:
Check the control unit for obvious signs
of damage to the case or its lid.
Check the action of the back tamper.
Check the condition of the control unit
standby battery.
Check the cabling to the keypad(s) and
expander(s) for signs of damage or
wear.
Check the keypads for obvious signs of
damage.
Test the action of all buttons on all
keypads.
Clean the keypad surface and display.
To clean the keypad wipe the surface
with a clean soft dry cloth. Do not use
water, solvents or any proprietary
cleaning materials.
Monitor the signal strength and battery
condition of all detectors, radio
keypads, remote controls, PAs and radio
sounders. Test each device. Replace
batteries as recommended by the
manufacturer‟s instructions.
Gently clean the lenses of any PIRs with
a clean, soft dry cloth. Do not use
water, solvents or any proprietary
cleaning materials.
Walk test all detectors.
Test any external sounders and strobes.
Note that if you wish to find the location of
any keypad or expander you can employ
the
Test – Locate Bus Device
option in the
Installer Menu. Use this option to make a
selected bus device give a continuous tone
from its sounder. Once you have found the
bus device you can silence the tone by
opening the case and so activating the
device‟s tamper.
5. Technical
Specification
General
Product name Menvier40 or Menvier100.
Product
Description
40 zone/100 zone hybrid
endstation with remote
keypads.
Manufacturer
Cooper Security Ltd.
Environmental Class II.
Operating
temperature
Tested -10 to +55°C.
Humidity
0 to 93% RH, non-
condensing.
Case material Steel.
Dimensions:
Control unit
320 x 400 x 98, mm HxWxD.
Keypad
115 x 156 x 30, mm HxWxD
Weight:
Control unit
4.9 kg (without stand-by
battery).
Keypad
0.26 kg
Capacities (Menvier40)
Zones
40 max (with expanders)
Outputs
40 max (with expanders)
Expanders and
Wired Keypads
20 max devices (see note)
Radio Keypads 5 max (two per radio
expander)
External Radio
Sirens
5 max (two per radio
expander)
WAMs
5 max (two per radio
expander, repeater mode
only)
Wards
5
Calendar Set
Timers
5 max
Log capacity
Up to 1,000 events: 750
mandatory events, 250 non-
mandatory. Stored in
EEPROM memory, available
for at least 10 years without
power.
User Codes
100 (plus installer code)
Remote controls 100 (one per user)
Radio Hold Up
Devices
100 (one per user)
Proximity tags 100 (one per user)
Note: Wired keypads, wired zone
expanders, and radio zone expanders are
all bus devices. You can connect any
combination of these devices to the bus.
Содержание Menvier 100
Страница 1: ...MENVIER SECURITY...
Страница 4: ...Menvier40 100 Page iv This page is intentionally blank...