Installation
Menvier40/100
Page 26
The display shows the time and date,
for example:
9. Key-in the default user 01 code to
silence the sounders.
The display shows:
10. Enter Installer Menu and then leave it
again.
The LEDs around the navigation key
should now be green. If they glow red
then there may be an alert for a missing
battery that needs acknowledgement.
To force the control unit to check the
battery:
11. Press
, key in 5678 (or 567800 for
Grade 3), press
again.
The navigation key LEDs should now
glow green.
Note: The log is protected and cannot be
erased by the Installer.
Restoring Factory Defaults Only
If you wish to restore all factory default
options, without defaulting the user and
installer access codes then:
1. From the Installer Menu select
System
Options – Restore Defaults – Factory Defaults
.
The display shows:
2. EITHER: Press
to go back to the
Installer Menu without changing
defaults.
OR: Press
to load defaults.
If you press
the display shows:
3. Press A or B to select the desired mode.
The display shows:
4. Press
or
to display the desired
Security Grade (“2” or “3”) on the
bottom line of the display and then
press
to select it.
The display shows:
5. Press
or
to display the desired
wiring type on the bottom line of the
display and then press
to select it.
The system loads all defaults except for
Access Codes and the Log.
The display briefly shows:
Followed by:
6. Press
until the display shows:
7. Press
.
The display shows:
The control unit scans the bus to see
what devices are attached and powered
up. After several seconds (depending on
the number of devices connected to the
bus) the display shows, for example:
The top line of the display shows the
number of new devices found. Because
you have restored factory defaults the
control unit has erased its internal list of
bus devices and the display will not
show any devices as missing. So, if a
device is attached to the bus but not
powered up then the control unit will
not detect it. The bottom line of the
display shows the first in the list of
found devices. Press
to see any other
items in the list.
8. Press
.
The display shows:
9. Press
.
The keypad sounder gives “deed ah”
confirmation tone and the display shows
the time and date, for example:
The control unit has saved all the
changes you have made.
Step 12. Commission
the System
Install Detectors and Other Peripherals
1. Use the Installer Menu to teach the
system the identity of any radio
detectors or other peripherals. (
You
must have a radio expander already
connected and installed on the bus to do
Содержание Menvier 100