Before connecting the cooker to the gas supply system, ensure that the appliance is compatible with the
local distribution conditions (nature of the gas and gas pressure). In the event of incompatibility, consult a
CORGI registered installer to make the necessary adaptations or adjustments.
Connection to an LPG cylinder
Alternatively, the hob can be connected to an LPG cylinder. In this case, LPG injector jets (not supplied -
contact the helpline) should be fitted to the burners by the qualified service engineer. Use a rubber hose
with a safety certificate to connect the applicance to the LPG cylinder.
Every time the hob has been connected to an LPG cylinder, check the cylinder valve for soundness and the
connection of the regulator to the cylinder and also its operation.
WARNING: Under no circumstances should the gas tightness be checked by means of a naked
flame (e.g with a match or candle) as there is a danger of explosion.
WARNING: Before starting any adjustments or changing the injectors, disconnect the appliance
from gas and mains electricity supply.
Electrical connection
The appliance must be properly connected to the mains supply by a qualified electrician according
to current safety regulations.
This appliance must be earthed.
1.
Release the cover plate by removing the cover screw (Figure 3).
2.
Loosen the cable clamp (Figure 3).
3.
Feed the mains connection cable through the grommet in the back panel and cable clamp. Connect the
mains supply cable to the terminal block on the cooker using the following colour code (Figure 3):
• The yellow/green wire should be connected to the earth terminal (
E
).
• The blue or black wire should be connected to the neutral terminal (N).
• The brown or red wire should be connected to the live terminal (L).
Secure the cable clamp. Check the cable terminals for tightness and ensure that the terminal links are in
place, then replace the cover plate and cover screw.
Figure 3 – electrical connections
LIVE
TERMINAL
NEUTRAL
TERMINAL
COVER PLATE
EARTH
TERMINAL
GROMMET
MAINS SUPPLY
CABLE
COVER SCREW