Cool Energy EcoStore Heat Pump Water Heater
27 |
P a g e
4.11 Hydraulic safety unit efficiency check
The hydraulic unit efficiency is very important to prevent any overpressures inside the tank (that
would damage it), and allows the user to safely operate the equipment. Periodically check the
efficiency of the hydraulic safety unit, according to the instructions provided by the manufacturer.
Follow the instructions provided by the manufacturer. During the check clean the unit and remove
any limestone scales.
4.12 Unit emptying
Should the unit be going to remain unused for a prolonged time, we recommend that you empty it.
In this case proceed as follows:
•
cut off the power supply and the main water supply;
•
open a hot water tap to allow air to flow in;
•
turn the emptying knob on the hydraulic safety unit to the open position;
•
verify that the discharge connector of the hydraulic safety unit is connected to a drain as
specified in par. 3.1.1.
4.13 Restart after a long term stop
When the unit is restarted after a long-term stop (trail running included), it is normal that outlet water
is unclean. Keep the tap on and the water will be clean soon.
5
MAINTENANCE INSTRUCTIONS
(qualified personnel only)
WARNING:
U
the repair and/or maintenance operations must only be performed by qualified
U
U
personnel, exclusively using genuine spare parts. Before performing any maintenance
U
U
operations, disconnect the equipment from the mains.
U
Before performing any maintenance operations we recommend that you purchase any
U
U
spare parts from the authorized dealers or directly from the Manufacturer.
5.1
General
•
Control regularly the connection between the supply plug and wiring.
•
In some cold areas (under 0°), if the system is not used for a long period, empty the boiler in
order to avoid freezing.
•
It is advised to clean regularly the inside part of the boiler and the electric resistance in order to
preserve the efficiency.
•
Control the magnesium anode and change it if needed.
•
Clean the air filters each month in order to preserve the heating performance.
•
Before turning off the system for a long period you must:
-
Remove the current supply;
-
Drain all the water from the tank and the pipes;
-
Close all valves;
-
Control regularly all inside components.