Cool Energy EcoStore Heat Pump Water Heater
28 |
P a g e
5.2
False errors of operation
•
Due to a start caused by a voltage fall, you must wait 3 minutes before the reactivation of the
compressor, in order to preserve its integrity.
•
If the auto protection is activated and the system stops, control that:
- When the supply indicator is on, if the system is being forced to function even without the
normal operative conditions; if the in-out air flow is blocked or if a strong wind blows towards
the air exit.
•
De-frosting
When there is humidity and cold, the condenser must be thawed and the efficiency of the air
heating is lower: the system will stop the water heating, will do the thaw and then will restart
the air heating.
•
During the defrosting, the compressor continues to work, while the fan stops.
•
The defrosting time varies between 3 and 10 minutes accordingly to the environmental
temperature and frosting.
5.3
Visualized temperature
•
When the system is stopped, a reduction of the temperature is normal due to the loss of heat.
When it goes bellow a few degrees, the system is automatically activated.
•
During the heating the water temperature could continue to decrease or could not increase
because of the exchange water heating. When the whole tank will get to the temperature the
system will stop automatically.
5.4
Refrigerating unit maintenance
The refrigerating circuit requires no maintenance.
Components are cleaned during the anode and tank maintenance.
5.5
Cleaning the aspiration air filter
Periodically the filter placed in the air entry opening is removed and cleaned in order not to
damage the system efficiency.
Rotate in counterclockwise sense the air entry
opening.
Lift and remove the opening.