Cool Energy EcoStore Heat Pump Water Heater
23 |
P a g e
4.5.6 Vacation mode
Method for Vacation mode setting:
Enter Vacation setting. Icon
will
flash. Icon
will be lightened.
will
show the last setting vacation days.
Set vacation days. The days range is 1~99
days.
Confirm Vacation setting and quit out. The
unit will immediately go into Vacation mode.
In vacation mode, the setting target water temperature is 15°C as default and will show the
remaining vacation days. On the last day of vacation, unit will automatically start disinfecting function,
and automatically reset the target temperature to the last one before vacation. If unit has already
been under vacation mode or OFF, press will lead to show invalid icon
on the
display.
4.6 Combination button
ICON
DESCRIPTION
Clear error code
+
Press the two buttons at the same time
to clear all stored error & protect codes,
and the buzzer will buzz one time.
Query mode
+
Press the two buttons at the same time
for 1sec to go into query mode.
Under query mode user can check unit
setting & running parameters by
pressing
toggles. Press button for
1s or no button
operation for
30s, then quit query mode.
4.7
Auto-restart
If electricity power failed, unit can memorize all setting parameters, unit will be back to the previous
setting when power recover.
4.8
Screen auto lock
If there is no operation of button for 30s, screen will be locked (extinguished) except for error code
and alarm light.
Press any button will unlock the screen(lighten).
Содержание EcoStore
Страница 16: ...Cool Energy EcoStore Heat Pump Water Heater 15 P a g e Water Temperature setting ...
Страница 36: ...Cool Energy EcoStore Heat Pump Water Heater 35 P a g e Fig 4 Hydraulic connection diagram Second Heat Source ...
Страница 41: ...Cool Energy EcoStore Heat Pump Water Heater 40 P a g e Fig 6 Electric connection ...