TROUBLESHOOTING PROCESS
The Water Witch is an accurate and reliable electronic auto leveller which should
provide you with many years of consistent performance.
If your Water Witch is not operating correctly upon installation or you suspect a fault after
years of reliable service, you will need to consider the problem being experienced and refer
to the fault table below:
Fault No.
Description
Details
1
FILL
The fill timer has exceeded its maximum run time. Consider
the following possibilities:
• Debris may be caught in sensor so it doesn’t recognise full
water level – check and clean sensor to ensure it operates
correctly.
• Sensor has failed and does not recognise full water level –
check the sensor operation and replace if required.
• Solenoid valve has failed and is not filling the pool. This
will be recognisable by a low water level. Replace the
solenoid valve and check the unit is operating correctly.
• Volume is set too low and fill timer exceeds run time
before full water level is attained – check volume is
correct for the water body. Alternatively, if this fault
occurred because a large volume of water was removed
from the pool, use the Manual Fill feature in the future.
• Sensor wiring is incorrect – check sensor plug is inserted
correctly and wiring to the three pins is as per the
following:
• Air-lock in the sensor balance line – check water level in
the balance line relative to the pool level.