106
M’Ax User Guide
Issue Number: 4
Appendix G
Flux Alignment
Use this procedure only in exceptional circumstances; do not use it
when setting up the Drive.
1.
Disconnect the load from the motor.
2.
Ensure the
Hardware enable
contact is open.
3.
If a
RUN
contact is connected, ensure that it is open.
4.
Apply the AC supply (or auxiliary back-up supply) to the Drive.
5.
Ensure parameter
6.08
Hold zero speed select is set at
0
.
6.
Close the
Hardware enable
contact.
7.
Check that the display shows
rdY
, or that parameter
0.01
is set at
1
.
8.
Set
5.12
Flux alignment test enable at
1
. When the test is
completed,
5.12
automatically returns to
0
.
9.
Re-enter the required settings into the appropriate parameters.
10. Remove the AC supply or auxiliary back-up supply; the new flux-
alignment value is automatically stored in the
SLM
.