Functions of Components
IPC-BX/M560(PCW)
57
I/O Addresses and Instructions
* 0139h: Watchdog timer control
R/W
D6
D5
D4
D3
D2
D1
D0
D7
Figure 5.8. WDT Control Port (0139h)
R
: Stops the watchdog timer and cancels the alarm. The data
read is undefined.
W
: Starts and clears the watchdog timer. The data to be
output can be undefined.
* 013Ah: Watchdog timer counter
R/W RESET: FFh(H) FFh(L)
D6
D5
D4
D3
D2
D1
D0
D7
D6
D5
D4
D3
D2
D1
D0
D7
Figure 5.9. WDT Counter Port (013Ah)
R
: Reads watchdog timer count data.
Watchdog timer counter time-out period data (16bits) is
read. Data is read twice in the L-to-H order. The value
read is output not as the current count value but as the
count data that has been set.
W
: Writes watchdog timer count data.
Watchdog timer counter time-out period data is written.
Data is written in the L-to-H order. The clock for the
watchdog timer counter is 4.58
µ
sec. The time-out period
is set as in the following examples:
0.5sec
à
006Dh
1sec
à
00DAh
4sec
à
0369h
8sec
à
06D2h
15sec
à
0CC6h
30sec
à
1996h
120sec
à
6658h
240sec
à
CCB1h