Functions of Components
IPC-BX/M560(PCW)
60
* 013Dh: Switch data
D6
D5
D4
D3
D2
D1
D0
D7
rsv*
rsv*
rsv*
R (RESET: XXXXXXX0B)
rsv*
rsv*
SW6
SW5
Figure 5.13. Switch Data (013Dh)
R
: Switch data
SW6 : SW1-6 data
0
: SW1-6 on
1
: SW1-6 open
SW5 : SW1-5 data
0
: SW1-5 on
1
: SW1-5 open
Note!
Do not change the setting for any " rsv" bit because it is system
reserved.
Setting the alarm-out output state
SW1-1 and SW1-2 can be used to set the alarm-out output state.
Table 5.18. Setting the Alarm-out Output State
(SW1-1, SW1-2)
WDT
WDT
WDT start
WDT time-out
OFF
OFF
OFF
OFF
OFF
ON
*
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
ON
* Factory Settings
External alarm output state
SW1
Power on
SW1-1 SW1-2
Power off
ALARM LED
If you set the PO2M (D7) bit of event output control (013Bh) to 1,
the ALARM LED on the front panel of the main unit comes on in
either of the following conditions:
• The watchdog timer (WDT) causes a time-out.
• 1 is written to the P2 (D2) bit of the general-purpose I/O port
(0138h).