Functions of Components
IPC-BX/M560(PCW)
48
Table 5.10. Register Functions
<4/4>
MSR : Modem Status Register
D7
D6
D5
D4
D3
D2
D1
D0
03FEH
I/O address
Contents
SCR : Scratchpad Register
03FFH
DCD RI
DSR CTS
DDCD TERI DDSR DCTS
Delta CTS
Delta DSR
Trailing edge RI
Delta data carrier detect
CTS
DSR
RI
DCD
8bit readable/writable register. The user can use this register for temporarily
saving data.
Since these status are
not used for RS-485,
data is invalid.
Setting the baud rate
The baud rate is set with software by dividing the clock input
(1.8432MHz). The baud rate is set by writing the corresponding
values to the divisor latch registers (LSB, MSB) as shown below:
Table 5.11. Baud Rate Settings
Setting error (%)
50
2304
---
75
1536
---
110
1047
0.026
134 .5
857
0.058
150
768
---
300
384
---
600
192
---
1200
96
---
1800
64
---
2000
58
0.69
2400
48
---
3600
32
---
4800
24
---
7200
16
---
9600
12
---
19200
6
---
Example: To set 9600bps, write 00 and 12 (decimal) to the divisor latch registers
(MSB and LSB), respectively.
Baud rate
Value written to divisor latch registers