Functions of Components
IPC-BX/M560(PCW)
61
General-purpose Inputs/Outputs and Remote Reset
The BOX-PC has three channels for both of general-purpose
insulated inputs and outputs. The inputs can also be used as
interrupt or remote reset inputs.
Specifications
[Inputs]
• Input specification
: Photocoupler-insulated current driven
input
• Input resistance
: 4.7k
Ω
• Number of
: 3 channels (including one which is also
input signals
available as a remote reset input. Bit
2 fixed)
• Bit available as
an interrupt input
: Bit 0 (fixed)
• Interrupt level
: NMI
• Input protection circuit : Provided with a reverse-connected
protection diode
• Input response time
: Within 100
µ
sec
• External circuit
power supply
: 12 to 24VDC (±10%)
[Outputs]
• Output specification
: Photocoupler-insulated open collector
output
• Output rating
: 30VDC Max., 100mA
• Number of
: 3 channels (including one which is also
output signals
available as a watchdog timer alarm
output. Bit 2 fixed)
• Output response time : Within 10
µ
sec
[Common]
• I/O address
: 0138h, 013Bh, 013Ch (Capable of
being set in 512bytes by the switch)