background image

I n d u s t r i a l   W o r k s t a t i o n  

A M B - 2 4 X X  

 

AMB -24xx series User Manual V1.2

 

1

 
 
 
 
 

 
 
 
 
 

 

  AMB-2427/2457/ 

2450 Series

 

12.1/15” TFT Flat-panel 

     Industrial Workstation

 

Содержание AMB-2427 Series

Страница 1: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 1 AMB 2427 2457 2450 Series 12 1 15 TFT Flat panel Industrial Workstation...

Страница 2: ...that this manual is in good condition If anything is missing or damaged contact your dealer immediately n An AMB 2427 2457 2450 Industrial workstation n An AMB 2427 2457 2450 User s manual Disk n A MB...

Страница 3: ...er outlet 9 Position the power cord so that people cannot step on it Do not place anything over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not...

Страница 4: ...F IT MAY DAMAGE THE EQUIPMENT FCC Safety This device complies with Part 15 FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this de...

Страница 5: ...7 Specifications 10 Basic Operations 14 Dimension 16 Rack Mounting 18 Hardware Installation 19 Exploded Diagram 20 Passive Back plane 22 Install CD ROM Hard Disk Drives and Floppy Disk Drive 24 Power...

Страница 6: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 6 General Information Chapter 1...

Страница 7: ...a rugged workstation chassis which provides protection from dust vibration and moisture The Modular System Design makes AMB 24xx series could open front with a key lock CD ROM FDD is secure in it Fro...

Страница 8: ...seal and captive hand screw to hold it closed In addition the door offers protection against accidental operation of the unit s controls Key Lock This design like a key make front panel open and close...

Страница 9: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 9 power indicators for 5 V 12 V 5 V and 12 V...

Страница 10: ...on Painted metal steel chassis aluminum alloy Disk drive housing One 3 FDD one slim CD ROM one 3 HDD Cooling system One 64 CFM fan Dimensions W x H x D 483 x 355 x 225mm AMB 2450 W x H x D 483 x 355 x...

Страница 11: ...color LCD TFT color LCD Size diagonal 15 12 1 8Number of Pixels 1024 W x 768 H 800 W x 600 H Dot size mm x mm 0 313 W x 0 329 H 0 3075 W x 0 3075 Contrast ratio 300 250 View angle Horizontal 160 120...

Страница 12: ...e the signals are connected to membrane keypad PS2 ports at front panel l Brightness control LCD backlight on off brighten increasing decreasing l Key Lock Lock front door open closed l Finger Mouse F...

Страница 13: ...resistive l Resolution 1024 x 1024 l RS 232 Interface l Support 8 wire touchscreen l Visible Light Transmission 68 550nm Refection 25 550nm l Provide DOS Windows 95 98 Windows NT 2000 Driver Environme...

Страница 14: ...o sealed membrane keypads one with 59 data keys and the other with 24 function keys or connect external keyboard for fast data key in Finger mouse could support the quick mouse course moving Make the...

Страница 15: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 15 2 Open front Panel function 3 Front Panel real side...

Страница 16: ...P O S 0 1 2 3 7 4 9 8 5 6 B A F E A L T A L T D C H G _ INS INS PgUp PgUp ESC ESC ESC ESC TAB TAB F17 F7 F13 F11 F12 F15 F14 F16 F3 F1 F 2 F5 F 4 F 6 F19 F18 F20 F 9 F8 F10 482 252 2 AMB 2457series ON...

Страница 17: ...435 2 23 3 355 325 339 8 10 51 174 AMB 2450 3v CTRL PgDn DEL 6 4 5 ENTER 1 S P A C E BACK S P A C E 2 3 _ Q Y U 7 Z 8 9 V R W S A E I M G F N J O K B C SHIFT 0 X T H P L D ALT INS PgUp TAB ESC F 1 F1...

Страница 18: ...e that all additional equipment has been installed correctly and that the cabling has been reattached See Fig 1 Turn on the front panel 2 Take off the transfer cable 3 Move up the front panel 4 Separa...

Страница 19: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 19 Hardware Installation Chapter 2...

Страница 20: ...Exploded Diagram The diagram shows all the components and parts that make up the AMB 24xx series Use as a guide when assembling and disassembling your system AMB 2427series 1 1 1 2 1 3 1 5 1 8 1 9 2 0...

Страница 21: ...24xx series User Manual V1 2 21 AMB 2457series 2 5 5 11 1 3 6 7 9 10 12 14 21 18 13 13 16 15 17 25 19 23 28 31 31 29 26 20 22 27 24 4 8 AMB 2450series 1 10 2 3 4 6 7 8 12 16 17 18 1 9 20 25 26 27 28...

Страница 22: ...orkstation each come with an ISA PCI bus 7 and 10 slots passive backplane For the purpose of either maintenance or upgrading please follow the steps to take the backplane off 1 Remove all the add on c...

Страница 23: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 23 10 slots passive back plane...

Страница 24: ...which fastened to its bay with screw on the both sides From the rear view there are three bays for installing disk drive on the bottom is for a 3 5 HDD then middle for a 3 5 FDD top of the disk driver...

Страница 25: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 25 3 Install HDD Cable 4 Install FDD Cable...

Страница 26: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 26 5 Install CD ROM Cable 6 Install in Chassis...

Страница 27: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 27 7 Fasten in chassis with two screws...

Страница 28: ...ly Replacement A universal 250W switching power supply is provided in the Workstation for other options please refer to Appendix B Ten screws shown in the following figure fix it Unfasten the six scre...

Страница 29: ...side of the chassis You are expected to clean and replace the filter in it form time to time and for that you don t need to strip the housing and take the whole unit off There is a small handle standi...

Страница 30: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 30 3 Install replace fan filter...

Страница 31: ...1 CPU Card Installation Signal transfer between CPU card and front panel via a transfer board The signal include Keyboard mouse VGA and touchscreen It will show how to connect them in the below photo...

Страница 32: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 32 From TB 908D to CPU card 1 From TB 908D to CPU card 2...

Страница 33: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 33 From TB 908D to CPU card 3...

Страница 34: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 34 VGA Jumper setting 15 LCD Panel Jumper setting on DV69K 12 1 LCD Panel Jumper setting on DV69K...

Страница 35: ...Industrial Workstation AMB 24XX AMB 24xx series User Manual V1 2 35 Power Supply Specification Appendix A...

Страница 36: ...iability Ball Bearing cooling fan l High precision and stable DC outputs for long term operation General Specifications Ripple and Noise The peak to peak ripple and noise for 12V is less than 140mV Th...

Страница 37: ...nal circuits The trip point of crowbar circuit is around 5 9V to 7 0V The power supply will go into hiccup mode against short circuit or over load conditions and will auto recovery while faulty condit...

Страница 38: ...nual V1 2 38 Selection Table Input Output spec at 40 Max Output Current Model Input voltage 5V 12V 5V 12V Universal 250W 85 265VAC 24A 10A 0 5A 0 7A 48VDC 250W 40 to 65VDC 25A 8A 1A 2A 24VDC 250W 18 3...

Отзывы: