REMOTE OPER. ACCESS, VIRTUAL PAD
NO YES
Select YES for remote access to the console.
The QUIT command ( Q, then Y to confirm) is displayed on screen:
♦
10 operation VT100
↔
(11 Minitel terminal operation)
♦
30 remote operation VT100
↔
(31 remote Minitel terminal operation) is used to
call the remote site (multi-site operation) to carry out remote operation via the
MMC server
♦
40 remote server VT100
↔
(41 remote server Minitel = used to call certain PBX
internal servers (AFISER, SRVRHM, KITAXE, MUFACT, SRVANN) .
Note:
The operation of VT100, Minitel, or Windows depends on the choice made in
ACCESS MODE.
COMPACT FORMAT HANDLING ACCESS
NO YES
This line is specific to the Management Centre.
ACCESS MODE
VT100 VT100 or PC MINITEL or VT100
MINITEL or PC or VT100
This field is used to define the console access mode.
ACTIVE SERVICE AT INIT.
VT100 MMC ----------
Selecting "--------" connects the Management Centre to the PBX as soon as the latter
initialises.
MODEM
REMOTE OPER. ACCESS, VIRTUAL PAD
NO YES
Select YES for remote access to the modem.
ACCESS MODE
MINITEL
MINITEL or VT100
MINITEL or PC or VT100
VT100
This field defines the remote access mode.