Page 220
15/09/2004
PS8149KENAA01
Ce document est la propriété de EADS et ne doit pas être reproduit ou communiqué sans autorisation.
This document is the property of EADS and may not be copied or circulated without authorisation.
TIME TO LIVE OF THE ARP INPUT SEC
Default value in seconds of the service life of an ARP cache input. This value can be
between 1 and 65534 seconds and is initialised at 600 (10 minutes) (parameter 4 in the
table).
TIME-OUT NETWORK ALARM START SEC
Timeout value used before an ethernet link is deemed to be disconnected (no LINK), which
will put the data links and VOIP trunks out of service. This value can be between 1 and
65534 seconds and is initialised at 120 (2 minutes) (parameter 7 in the table).
TIME-OUT NETWORK ALARM END SEC
Timeout value used before an ethernet link is deemed to be reconnected (LINK re-
enabled), which will put the data links and VOIP trunks back in service. This value can be
between 1 and 65534 seconds and is initialised at 30 (parameter 8 in the table).