Page 22
15/09/2004
PS8149KENAA01
Ce document est la propriété de EADS et ne doit pas être reproduit ou communiqué sans autorisation.
This document is the property of EADS and may not be copied or circulated without authorisation.
3.2.2
PROCEDURE FOR INSTALLING A CARD
Warning:
♦
Before disabling a card, all the equipment interfaces on that card must first be
disabled.
♦
A card which supports an attendant console, a night console trunk group
declared in a trunk group cannot be changed to the status NOT EQUIP. This
equipment must be deleted beforehand.
♦
If no network link is connected to the PTx card, no TCP gateway link can be
enabled.
IMPORTANT:
Always switch off your device before installing or uninstalling a card,
unless it is an LA16X or LN16X card in an XL cabinet (F6).
3.2.2.1 F1/F2
1.
Set all the equipment interfaces on the card out of service (DISABLED).
2.
Delete all the directory numbers assigned to the equipment interfaces on the card in
menu 1-1-1 (Extension characteristics).
3.
Change the status of the carte from
In service
to
Not equip.
4.
Power off the PBX (Switch on the face plate of the power supply module) in the main
cabinet or the expansion cabinet.
5.
Remove the card from the PBX.
6.
Insert the new card.
7.
Power on the PBX (Switch on the face plate of the power supply module) in the main
cabinet or the expansion cabinet.
8.
Select the card type and validate the status
In service
(wait until the download is
complete).
9.
If you are installing a subscriber card, redefine the directory numbers in menu 1-1-1
(Extensions characteristics).
Note:
Changing the status of the card from
In service
to
Not equip.
destroys all the
links previously created. For a PT2 card to keep the links created when changing
from x channels to y channels, change the status of the card from
In service
to
Disabled
(instead of
Not equip.
).