Page 32
15/09/2004
PS8149KENAA01
Ce document est la propriété de EADS et ne doit pas être reproduit ou communiqué sans autorisation.
This document is the property of EADS and may not be copied or circulated without authorisation.
Note:
The CLA card is a reduced version of the CLM card, with 4 asynchronous V24
interfaces (channels: 0, 1, 14, 15). It is downloaded using the CLM field
The
CCP
card can only be fitted in cabinet 0.
Reminder:
The ADB card is used to connect 6 T0 BRIs to the ISDN (NUMERIS), of
which 2 interfaces can be converted to S0 for ISDN terminals. There are
six interfaces, each with two 64 kb/s B channels and one 16 kb/s D
channel. This card is put in service automatically.
SOFTWARE
SW. CLD
CARD
SW. CLE
CARD
SW. CLM
CARD
SW. CLF
CARD
This field indicates the software to be downloaded according to the CLx card type selected
on the Type field.
CAUTION:
There is no compatibility check between the software requested and the
card to be downloaded.
THIS FIELD MUST BE USED WITH CARE.
STATUS
OUT OF SERVICE
IN SERVICE
NOT EQUIP.
NET. ALARM
IN SERVICE
Status assigned automatically on Total Reset: this only applies to cards
identified as ANALOG, DIGITAL, D DATA, ANALOG TK.,
ISDN T0 (ADB card) and ISDN T2 (ADP card).
For the PCM LRN-1, PCM LRN- 2, TIE-LINE A, B, C, D, ISDN T0/S0
(LAS), T2/S2, or CLX cards, validate the status by pressing RETURN
or ENVOI.
OUT OF
SERVICE
This status is used to put a card temporarily out of service. The
equipment interfaces connected are also put OUT OF SERVICE.
NOT EQUIP.
This status is important because it is used to replace one card with
another of a different type (for example, replacing an analogue card
with a digital one, etc.).
NET. ALARM
LSB status for NETWORK cards (in particular PVI)
which indicates network disconnection (IP, ISDN,
etc.).
PUTTING THE LAS CARD IN SERVICE
IMPORTANT:
Before putting the LAS card in service, you must first configure the
IFS link (see below).