PS8149KENAA01
15/09/2004
Page 163
Ce document est la propriété de EADS et ne doit pas être reproduit ou communiqué sans autorisation.
This document is the property of EADS and may not be copied or circulated without authorisation.
5.3 CONNECTION
MANAGEMENT
(MENU 5-3) NOT IN VALUES
For the Call Manager (F5): this menu is not available.
CONNECTION MANAGEMENT
CALL
1
- PHYSICAL SLOT A
…..
- PHYSICAL SLOT B
…..
- PHYSICAL SLOT C
…..
-
TONE SILENCE
- COMMAND TYPE
disconnect.
CALL
2
- PHYSICAL SLOT A
…..
- PHYSICAL SLOT B
…..
- PHYSICAL SLOT C
…..
-
TONE SILENCE
- COMMAND TYPE
disconnect.
--------------------------------------------------
Figure 142: Menu 5-3 (Connection management)
This menu is used to set up unilateral, bilateral or 3-party connections between designated
circuits on tones, on demand.
This menu offers the possibility of setting up 2 separate calls and to check the PBX
transmission plan, between TRK -> SET and SET -> TRK (PSTN check).
CALL 1
PHYSICAL SLOT A
Indicate the physical slot of the first equipment for the first call.
PHYSICAL SLOT B
Indicate the physical slot of the second equipment for the first call.
PHYSICAL SLOT C
Indicate the physical slot of the third equipment for the first call.
TONE
SILENCE
TONE 330 HZ
TONE 440 HZ HIGH
TONE 440 HZ LOW
TONE 440 + 330 HZ
INTERNAL MUSIC
EXTERNAL MUSIC
Select the type of tone (call 1).