PS8149KENAA01
15/09/2004
Page 149
Ce document est la propriété de EADS et ne doit pas être reproduit ou communiqué sans autorisation.
This document is the property of EADS and may not be copied or circulated without authorisation.
4.7.8.2
DISPLAY FLOWS BY CAC CLASS (MENU 4-7-8-2)
For the Call Manager (F5): Menu 4-7-3-2 (Disp. flow per class)
DISP. FLOW PER CLASS
ACTIVE SERVER: 001-SITE LOC, CCU: 2
CLASS
THROUGPT MAX.
CRIT NB
REF NB
-----------------------------------------------------------
0
0
0
0
0
1
0
0
0
0
2
0
0
0
0
-----------------------------------------------------------
Figure 129: Display flows by CAC class
Only CAC class counters with limited flow are displayed. These counters are read in the
active server
ACTIVE SERVER: XXXXX, CCU: ZZ
This line shows the name of the site where the active server is located (counters read in
this server) and the cluster number (cluster no. 2 for "single-cluster" systems).
CLASS
shows the number of the class.
THROUGPT
Shows the current flow (in kbit/s).
MAX
Shows the maximum current flow reached.
NO CRIT
Shows the number of calls in a critical area.
NB REF
Shows the numer of calls refused.