DX-1S Digital PABX - Programming Manual
5-10
5.1.38 PROGRAMMING ITEM 37 : SMDR DIGITS SELECTION
This item is to select the first few digits of the dialed number to be printed in SMDR to protect privacy.
Command
3 * 37 * Value <Enter>
where Value = 1 ~ 24 (digits)
Default Value
Default = 24 (digits)
5.1.39 PROGRAMMING ITEM 38 : DIRECTORY NUMBER FORMAT
This item determine how many digits the directory number is.
If there are less than 50 extensions installed in a system, the Directory Number may be programmed to
two digits.
If there are more than 50 extensions installed in a system, the Directory Number must be programmed to
three or four digits.
Command
3 * 38 * Value <Enter>
where Value = 2 ~ 4 (digits for extension directory number)
Example
3 * 38 * 2 - to program the directory number to be 2 digits (10 ~ 59)
3 * 38 * 3 - to program the directory number to be 3 digits (100 ~ 599)
3 * 38 * 4 - to program the directory number to be 3 digits (1000 ~ 5999)
Default Value
Default = 4 (digits)
Related Topic
1.
Programming Item 87 - Directory Number Assignment
5.1.40 PROGRAMMING ITEM 39 : TRUNK GROUP ACCESS FORMAT
This item determine how many digits are the Specified Trunk Group Access Code.
If there are less than ten trunk groups in a system, the Specified Trunk Group Access Code may be
programmed to two digits.
If there are more than ten trunk groups in a system, the Specified Trunk Group Access Code must be
programmed to three digits.
Command
3 * 39 * Value <Enter>
where Value = 2 ~ 3 (digits for Trunk Group Access Group)
Example
3 * 39 * 2 - to program the Specified Trunk Group Access Codes to be 2 digits (71 ~ 79)
3 * 39 * 3 - to program the Specified Trunk Group Access Codes to be 3 digits (701 ~ 716)
Default Value
Default = 3 (digits)
5.1.41 PROGRAMMING ITEM 40 : OPERATOR / DEFAULT TRUNK GROUP ACCESS CODE
This item determine which numbers between “0” and “9” are the Access Code of Operator and Default
Trunk Group.
Command
3 * 40 * Value <Enter>
where Value = 0 : Operator Access Code = 0 and Default Trunk Access Code = 9
Value = 9 : Operator Access Code = 9 and Default Trunk Access Code = 0
Default Value
Default = 0 : Operator Access Code = 0 and Default Trunk Access Code = 9