77
•
The pump body is fi lled with the liquid to be conveyed via the fi lling nozzle.
•
To do this, open the fi lling nozzle on the pump and fi ll the pump housing.
•
After completion of the fi lling nozzle again close leakage-free,
Emptying pump housings
• Make sure that the pressure/ and suction line may be under pressure and may contain liquid, if
necessary draining;
• Open the emptying nozzle - the liquid runs out of the pump housing:
• After the pump housing is completely emptied, close the emptying nozzle properly.
10
OPERATING STATES OF THE
CONEL FLOW RAIN-CHAMPION
10.1 SECURITY
DANGER: Danger to life:
• All activities at Conel Flow Rain-Champion may only be carried out by profes-
sional and knowledgeable personnel, who have been suffi ciently informed by
studying the operating instructions in-depth.
• Do NOT wear your personal protective gear and do NOT work with wet hands
or wet feet or stand in the water – avoid a fatal electric shock.
• Refer to unauthorized persons (especially children, adolescents) or animals
from the fi eld of work and activity.
10.2
NORMAL COMMISSIONING
To start up the Conel Flow Rain-Champion after a long downtime or after an off-shoot, proceed as
follows:
• Visual inspection and memory check for proper condition;
¾
Is there enough rainwater in the reservoir (refi ll with drinking water if necessary)?
¾
Is the suction sieve on the suction line clean and correctly positioned?
¾
Is the level sensor properly fi xed and placed in the correct position?
¾
Is the counterweight still in the correct position?
¾
Can the fl oat switch move freely and is not restricted by obstacles in its function?
• Visual inspection and check that all pipe and connections do not have leaks;
¾
Control the connection of the drinking water supply;
¾
Control the connections of the pressure/suction line;
•
visual inspection and inspection of the fl oat switch in the feed-in tank;
¾
To do this, slide the metal plate up on the feed-in tank and remove it – after that you have free
access to the fl oat switch:
¾
Check the seat and function of the fl oat switch.
-
Can the swimmer move freely in tank and is not restricted by obstacles in his function?
¾
Does the fl oat valve close and open properly?
• Visual inspection and control of electrical connections,
¾
Are all electrical connections properly and fi rmly connected?
¾
Is the required grid supply available?
•
Open the ball valve of the drinking water supply - the feed tank is fi lled;
• The operating mode switch in position „Automatic (Auto. )“;
• Insert the power plug (protective contact plug) into the protective contact socket provided for this
purpose;
• The pump switch switches on the pump and it begins to pump rainwater from the storage tank;
Содержание Flow Box
Страница 1: ...1 REGEN MEISTER MIT FÜLLSTANDSENSOR RAIN CHAMPION WITH LEVEL SENSOR D GB ...
Страница 2: ...2 ...
Страница 3: ...3 Technische Änderungen vorbehalten Für Druckfehler wird keine Haftung übernommen ...
Страница 87: ...87 ...