37
Brief description of the LED signals and control elements
LED row 1 m³/h
/
Indicates the setting of the limit for the maximum permissible water flow.
/
Indicates at half luminosity, when water is being drawn, the instantaneous wa-
ter flow.
/
Flashes if the water flow limit value is exceeded.
LED row 2 m³
/
Indicates the setting of the limit for the maximum permissible water volume.
/
Indicates at half luminosity, when water is being drawn, the current total water
volume that has flowed.
/
Flashes if the max. permissible water volume is exceeded.
LED row 3 h
/
Indicates the setting of the limit for the maximum permissible drawing time.
/
Indicates at half luminosity, when water is being drawn, the instantaneous
drawing time.
/
Flashes if the max. permissible water drawing time is exceeded.
“Flow” LED
/
Flashes if there is a water flow.
“Holiday” LED
/
Illuminates when holiday mode is active.
/
Illuminates together with the “Closed” LED when shut-off in holiday mode.
“Fault” LED
/
Flashes if the shut-off valve has an electrical or mechanical defect.
/
Illuminates if a DIP switch is set incorrectly. In addition the LED row to which
the incorrectly set DIP switch is assigned flashes. If DIP switch S4 is set incor-
rectly, the yellow “Holiday” LED flashes.
“Open” LED
/
Illuminates if the shut-off valve is open.
/
Flashes while the shut-off valve is opening.
/
Illuminates together with the red “Closed” LED, if standby mode is active.
“Closed” LED
/
Illuminates if the shut-off valve is closed.
/
Flashes while the shut-off valve is closing.
/
Illuminates together with the green “Open” LED, if standby mode is active.
DIP switch S1
/
Setting of the limit for the maximum permissible water flow “m³/h”
DIP switch S2
/
Setting of the limit for the maximum permissible water volume “m³”
DIP switch S3
/
Setting of the limit for the maximum permissible drawing time “h”
DIP switch S4
/
Setting of holiday mode
“Manual” pushbut-
ton
/
Manual opening/closing of the shut-off valve
/
Ending of holiday mode
/
Starting and ending of standby mode
Содержание CLEAR 2.0 SAFE
Страница 12: ...12 6 BETRIEB Abb 5 CLEAR 2 0 SAFE mit abgenommener Abdeckhaube Abb 6 CLEAR 2 0 SAFE Schaltung...
Страница 36: ...36 6 OPERATION Fig 5 CLEAR 2 0 SAFE with removed cover Fig 6 CLEAR 2 0 SAFE switch...
Страница 60: ...60 6 EKSPLOATACJA Rys 5 CLEAR 2 0 SAFE ze zdj t os on Rys 6 CLEAR 2 0 SAFE uk ad elektryczny...
Страница 74: ...74 Notizen Notes Notatki...