Troubleshooting:
Opening of devices and replacement of parts subject to water pressure must only
be performed by licensed persons to ensure the safety and leak-tightness of the
devices.
Fault
Cause
Remedy
Control sensor does not close, e.g.
if the manual pushbutton is
pressed.
No mains voltage (all LEDs off).
Ensure power supply unit OK!
Control sensor defective.
Notify customer service!
Control sensor does not open if
the manual pushbutton is
pressed.
No mains voltage (all LEDs off).
Ensure power supply unit OK!
Control sensor defective.
Notify customer service!
Unplug the power supply unit,
manually turn the shut-off valve
to the desired position (see
The red “Fault” LED illuminates.
Control sensor defective, the
open or closed position can no
longer be reached.
Unplug the power supply unit and
plug back in after a short period! If
the error occurs again, notify cus-
tomer service!
Unplug the power supply unit,
manually turn the shut-off valve
to the desired position (see
The red “Fault” LED illuminates
and one LED row also flashes.
DIP switch set incorrectly. Only
one contact of the 6-way DIP
switch may be closed.
Set the DIP switch according to
“Flow” LED does not flash, al-
though water is flowing.
Turbine blocked or electrical cir-
cuit defective.
Notify customer service!
Содержание CLEAR 2.0 SAFE
Страница 12: ...12 6 BETRIEB Abb 5 CLEAR 2 0 SAFE mit abgenommener Abdeckhaube Abb 6 CLEAR 2 0 SAFE Schaltung...
Страница 36: ...36 6 OPERATION Fig 5 CLEAR 2 0 SAFE with removed cover Fig 6 CLEAR 2 0 SAFE switch...
Страница 60: ...60 6 EKSPLOATACJA Rys 5 CLEAR 2 0 SAFE ze zdj t os on Rys 6 CLEAR 2 0 SAFE uk ad elektryczny...
Страница 74: ...74 Notizen Notes Notatki...
Страница 75: ...75 Notizen Notes Notatki...